A fix is available
APAR status
Closed as program error.
Error description
ENVIRONMENT: IBM Tivoli Monitoring for System p - CEC Base Agent 6.2.2.2 PROBLEM DESCRIPTION: Starting with VIOS 2.2.1, the lspartition -all command in an IVM environment will no longer display the VIOS itself. Since the CEC Base agent is dependent on the output of the lspartition command, the agent will not be able to monitor the VIOS itself. Another side effect is that the partitions listed might show incorrect data for the LPARs that are listed as monitored. This only affects the CEC Base agent running on IVM VIOS 2.2.1 or above. Non-IVM systems do not have this problem. RECREATE INSTRUCTIONS: Run the CEC Base agent on IVM VIOS 2.2.1 or above.
Local fix
Problem summary
*************************************************************** * USERS AFFECTED: Agent running on IVM. *************************************************************** * PROBLEM DESCRIPTION: The agent will not display the VIOS as * a monitored LPAR. *************************************************************** * RECOMMENDATION: Apply 6.2.2.2-TIV-ITM_CEC_BASE-IF0005. *************************************************************** Interim Fix 6.2.2.2-TIV-ITM_CEC_BASE-IF0005 resolves the problem by working around the broken IVM lspartition command.
Problem conclusion
The fix for this APAR is contained in the following maintenance package: | interim fix | 6.2.2.2-TIV-ITM_CEC_BASE-IF0005
Temporary fix
Comments
APAR Information
APAR number
IV41516
Reported component name
ITM SE SYSP CEC
Reported component ID
5724C04CB
Reported release
622
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-05-02
Closed date
2014-08-26
Last modified date
2014-08-26
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
ITM SE SYSP CEC
Fixed component ID
5724C04CB
Applicable component levels
R622 PSY