Fixes are available
APAR status
Closed as program error.
Error description
APAR Type: Field Approver: JM for XS Severity: 2 Reported Release: 623 FP2 Compid: 5608A41CI Distributed Installer Abstract: Remote Deploy of KQ7 agent from 6.2.3 MS Apps CD will deploy and configure at ITM release 6.2.3 FP1, but fails at 6.2.3 FP2. Environment: Windows only. Appears to be a regression from 6.2.3 FP1 to 6.2.3 FP2. Problem Description: See abstract. This error also occurs when either silent install or Remote Deploy is used to install and automatically configure the agent with default settings. Recreate Instructions: 1. Install ITM 6.2.3 FP2 on the endpoint. 2. Addbundles for the MS Apps CD release 6.2.3 IIS Agent code KQ7 to an existing TEMS that the endpoint in 1 connects to. 3. Deploy the KQ7 agent to the endpoint. 4. The deploy should configure the instance and allow the agent to connect to the TEMS but it doesn't.
Local fix
Configure the KQ7 agent at the endpoint via Manage Tivoli Enterprise Monitoring Services (MTEMS-kinconfg.exe).
Problem summary
Remote deployment of ITCAM for IIS 6.23 agent (KQ7) fails to configure at IBM Tivoli Monitoring release 6.23 FP2. When remote deploying the IBM Tivoli Composite Application Manager for Microsoft Internet Information Services (IIS) Agent version 6.23, if the endpoint is a Windows system and the IBM Tivoli Monitoring OS agent on the endpoint is version 6.23 FP2, the ITCAM IIS agent is incorrectly configured and the agent is not started.
Problem conclusion
The code was changed to correctly configure the agent. The fix for this APAR is contained in the following maintenance packages: | fix pack | 6.2.3-TIV-ITM-FP0004 | fix pack | 6.3.0-TIV-ITM-FP0001
Temporary fix
Reconfigure the ITCAM for IIS Agent (KQ7) agent on the endpoint.
Comments
APAR Information
APAR number
IV36526
Reported component name
OMEG DIST INSTA
Reported component ID
5608A41CI
Reported release
623
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-02-09
Closed date
2013-04-05
Last modified date
2013-10-14
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
OMEG DIST INSTA
Fixed component ID
5608A41CI
Applicable component levels
R623 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSTFXA","label":"Tivoli Monitoring"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"623","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
14 November 2022