PROBLEM DESCRIPTION: In klzagent, when running situations for Process Short Term Avg CPU metrics, the time used to calculate the averages is not properly calculated. And the resulting metrics are not available for the attributes: - Process Short Term Avg User CPU (Percent) - Process Short Term Avg System CPU (Percent) - Process Short Term Avg Busy CPU (Percent) This is showed in the klzagent trace log, setting the trace at level ERROR (UNIT:PROC ALL) This APAR can be identified because in the trace logs there are records such as: procnorm.cpp,515,"collectMetrics") Seconds elapsed - <0>:<0> where the Seconds elapsed does not change in time and always remains <0>:<0>
Local fix
Problem summary
Not available values for short term process cpu attributes In the Monitoring Agent for Linux OS, when running situations for Process Short Term Avg CPU metrics, the time used to calculate the averages is not properly calculated and the resulting metrics are not available for the attributes: - Process Short Term Avg User CPU (Percent) - Process Short Term Avg System CPU (Percent) - Process Short Term Avg Busy CPU (Percent). The above attributes are available only inside situations, therefore the problem is experienced when situations on those attributes are started.
Problem conclusion
The code was modified to calculate the proper time. The fix for this APAR is going to be included in the following maintenance vehicle: | fix pack | 6.2.3-TIV-ITM-FP0004 | fix pack | 6.3.0-TIV-ITM-FP0001
Temporary fix
Comments
APAR Information
APAR number
IV33846
Reported component name
ITM AGENT LINUX
Reported component ID
5724C04LN
Reported release
622
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-12-20
Closed date
2013-01-31
Last modified date
2013-10-10
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
ITM AGENT LINUX
Fixed component ID
5724C04LN
Applicable component levels
R622 PSY
UP
R623 PSY
UP
[{"Line of Business":{"code":"LOB45","label":"Automation"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSTFXA","label":"Tivoli Monitoring"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"622"}]
Document Information
Modified date:
30 December 2022