Readmes are available
IBM Netcool System Service Monitor SSM 4.0 Fix Pack 12 README 4.0.0-TIV-SSM-FP0012
IBM Netcool System Service Monitor SSM 4.0 Fix Pack 13 README 4.0.0-TIV-SSM-FP0013
IBM Netcool System Service Monitor SSM 4.0 Fix Pack 14 README 4.0.0-TIV-SSM-FP0014
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 1 README 4.0.0.14-TIV-SSM-IF0001
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 2 README 4.0.0.14-TIV-SSM-IF0002
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 3 README 4.0.0.14-TIV-SSM-IF0003
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 4 README 4.0.0.14-TIV-SSM-IF0004
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 5 README 4.0.0.14-TIV-SSM-IF0005
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 6 README 4.0.0.14-TIV-SSM-IF0006
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 7 README 4.0.0.14-TIV-SSM-IF0007
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 8 README 4.0.0.14-TIV-SSM-IF0008
IBM Netcool System Service Monitor SSM 4.0 Interim Fix 1 README 4.0.0.15-TIV-SSM-IF0001
APAR status
Closed as program error.
Error description
An arithmetic expression containing min and max functions together doesn't return results after arControlWindow samples as it should.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * SSM 4.0 Users using arithmetic subagent * **************************************************************** * PROBLEM DESCRIPTION: * * An arithmetic expresion that contains a min function would * * return results after arControlWindow samples. * * Similarly an arithmetic expresion that contains a max * * function would return results after arControlWindow samples. * * However if an arithmetic expresion contains both a min and * * max function in a single expression, no results are returned * * until after 2*arControlWindow samples. This is incorrect it * * should return results after just arControlWindow samples. * **************************************************************** * RECOMMENDATION: * * Upgrade to Fix Pack 12 for SSM 4.0. * ****************************************************************
Problem conclusion
Ensured that expressions containing min and max correctly return results after arControlWindow samples. The fix for this APAR is contained in the following maintenance packages: | fix pack | 4.0.0-TIV-SSM-FP0012
Temporary fix
Comments
APAR Information
APAR number
IV08138
Reported component name
NETCOOL SYS SVC
Reported component ID
5724P4300
Reported release
400
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2011-09-22
Closed date
2011-09-22
Last modified date
2011-09-22
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
NETCOOL SYS SVC
Fixed component ID
5724P4300
Applicable component levels
R400 PSY
UP
Document Information
Modified date:
22 September 2011