IBM Support

IV04110: TACMD EDITSIT -L FILE -P DIST=".." TRUNCATES DIST AT BYTE 4168

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When copying a situation's DISTRIBUTION value, if value is more
    than 4168 bytes in length the resultant DISTRIBUTION value in
    written to file specified per -l switch will be truncated, thus
    loss of data for DISTRIBUTION value.
    

Local fix

  • The 'missing', truncated data can be manually added by editing
    the file that was specified per the -l switch.
    

Problem summary

  • tacmd editsit -l truncates DISTRIBUTION value > 4168 when
    updating XML file
    
    When using the -l option of 'tacmd editsit -l
    <myFavoriteSit.xml>' if the DISTRIBUTION property has a value
    that is more than 4168 bytes the resulting DISTRIBUTION property
    value written out to <myFavoriteSit.xml> is truncated.  This
    usually results in the XML file, <myFavoriteSit.xml> in this
    example, being malformed and thus it can not be 'imported' via
    tamcd createsit or otherwise.
    

Problem conclusion

  • Corrected 'computed' buffer pointer to prevent loop logic from
    prematurely stopping the writing of DISTRIBUTION value to
    <myfavoriteSit.xml> output file.
    
    
    The fix for this APAR is contained in the following maintenance
    packages:
    
      | fix pack | 6.2.2-TIV-ITM-FP0006
    

Temporary fix

Comments

APAR Information

  • APAR number

    IV04110

  • Reported component name

    TEMS

  • Reported component ID

    5724C04MS

  • Reported release

    622

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-08-02

  • Closed date

    2011-08-12

  • Last modified date

    2011-09-29

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TEMS

  • Fixed component ID

    5724C04MS

Applicable component levels

  • R622 PSY

       UP

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSCTLMP","label":"ITM Tivoli Enterprise Mgmt Server V6"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"622","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information