IBM Support

IT40128: "... FRAGMENT BY RANGE ... STORE IN(D1,D2)" WORKS WHEN THE DBSPACES HAVE A DIFFERENT PAGE SIZE

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • Example:
    
    Dbspaces
    address          number   flags      fchunk   nchunks  pgsize
    flags    owner    name
    50f7cdd0         9        0x20001    9        1        2048
    N  BA    informix d7
    50fcbde0         10       0x20001    10       1        8192
    N  BA    informix d8
    
    
    create index ....
      fragment by range(c1) interval(1) store in(d7,d8)
    
    ... works, but should return the following error:
    
    -793    Page size of the dbspace does not match page size of the
    table or index.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * Users of Informix Server prior to 14.10.xC9.                 *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * See Error Description                                        *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * Upgrade to Informix Server 14.10.xC9.                        *
    ****************************************************************
    

Problem conclusion

  • Fixed in Informix Server 14.10.xC9.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT40128

  • Reported component name

    INFORMIX SERVER

  • Reported component ID

    5725A3900

  • Reported release

    E10

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2022-03-03

  • Closed date

    2022-09-30

  • Last modified date

    2022-09-30

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    INFORMIX SERVER

  • Fixed component ID

    5725A3900

Applicable component levels

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSGU8G","label":"Informix Servers"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"E10","Line of Business":[{"code":"LOB10","label":"Data and AI"}]}]

Document Information

Modified date:
30 September 2022