IBM Support

IT39316: A CHUNK ADDED WITH STORAGE PROVISIONING IS NOT NOT ROLLED BACK ON THE SECONDARY WHEN IT WAS A LONG TRANSACTION

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • The customer has enabled storage provisioning and encountered a
    situation where a chunk has been added to a secondary in error.
    This means that the two servers are now out-of-sync with regards
    to dbspace / chunk information and replication needs to broken
    and setup again.   The adding of the chunk became a long
    transaction which was aborted and rolled back on the primary but
    not the secondary.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * Users of Informix Server prior to 12.10.xC16 and 14.10.xC8.  *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * See Error Description                                        *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * Upgrade to Informix Server 12.10.xC16 or 14.10.xC8.         *
    ****************************************************************
    

Problem conclusion

  • Fixed in Informix Server 12.10.xC16 and 14.10.xC8.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT39316

  • Reported component name

    INFORMIX SERVER

  • Reported component ID

    5725A3900

  • Reported release

    C10

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2021-12-06

  • Closed date

    2022-04-07

  • Last modified date

    2023-05-15

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    INFORMIX SERVER

  • Fixed component ID

    5725A3900

Applicable component levels

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSGU8G","label":"Informix Servers"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"C10","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
16 May 2023