IBM Support

IT36068: SWITCHES REMOVED BUT FABRICS REMAIN AND CAUSE PROBES TO FAIL

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Several fabrics were decommissioned and removed from Network
    Advisor. Tried to remove them from Spectrum Control and only
    the switches were removed. The empty fabrics remained
    unexpected. Additionally, an old unreachable Network Advisor
    data source was incorrectly being referenced. Due to these
    issues, the probes continued to fail, even for the valid
    fabrics.
    
    Could not clean up the environment by only editing
    the connection info and using remove from database. Required
    manual database cleanup.
    
    - Empty fabrics left behind after all their switches were
    deleted.
    - CIMOM left behind even if it did not monitor anything.
    - Failed probe logs did not contain any error or warning
    messages about the failure.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * IBM Spectrum Control users with multiple Brocade CIMOMs      *
    * managing the same switches                                   *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * Fabrics, Ports, and Brocade CIMOMs are left behind after     *
    * switch deletion, without any possibility of deleting them    *
    * from                                                         *
    * WebUI.                                                       *
    *                                                              *
    * This fix will make it possible to delete empty Fabrics       *
    * (ie, with no switch) from the WebUI. Deleting them will also *
    *                                                              *
    * delete the leftovers CIMOMs which used to manage them.       *
    *                                                              *
    *                                                              *
    * The scenario encountered was several fabrics were            *
    * decommissioned and removed from Network Advisor.             *
    * Then attempted to remove them from Spectrum Control          *
    * and only the switches were removed. The empty fabrics        *
    * remained unexpectedly.                                       *
    *                                                              *
    * Additionally, an old unreachable Network Advisor data        *
    * source was incorrectly being referenced.                     *
    *                                                              *
    * Due to these issues, the probes continued to fail, even      *
    * for valid fabrics.                                           *
    *                                                              *
    * Could not clean up the environment by editing the            *
    * connection info and using remove from database. It           *
    * required manual database cleanup.                            *
    *                                                              *
    * - Empty fabrics left behind after all their switches were    *
    * deleted.                                                     *
    *                                                              *
    * - CIMOM left behind even if it did not monitor anything.     *
    *                                                              *
    * - Failed probe logs did not contain any error or warning     *
    * messages about the failure.                                  *
    *                                                              *
    *                                                              *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • The fix for this APAR is targeted for the following release:
    
    IBM Spectrum Control 5.4.4   [ 5.4.4-IBM-SC ]
    ( release target 3Q 2021 / August )
    
    http://www.ibm.com/support/docview.wss?&uid=swg21320822
    The target dates for future releases do not represent a formal
    commitment by IBM. The dates are subject to change without
    notice.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT36068

  • Reported component name

    TPC

  • Reported component ID

    5608TPC00

  • Reported release

    536

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2021-03-01

  • Closed date

    2021-06-18

  • Last modified date

    2021-06-18

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TPC

  • Fixed component ID

    5608TPC00

Applicable component levels

[{"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSNE44","label":"Tivoli Storage Productivity Center"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"536"}]

Document Information

Modified date: