IBM Support

IT35563: EXECUTE PROCEDURE RETURNS ERROR 934 CONNECTION TO REMOTE SITE NOLONGER VALID IN DISTRIBUTED QUERY AFTER REMOTE NODE BOUNCE

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • Execute procedure returns error 934 'Connection to remote site
    no longer valid' in distributed query after remote node bounce.
    
    Execute procedure on server A is selecting from server B.  When
    remote server B is bounced and the same procedure is run on
    same session on server A, it returns the error 934 'Connection
    to remote site no longer valid'.
    

Local fix

  • Execute procedure again in same session.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * Users of Informix Server prior to 12.10.xC15 and 14.10.xC7.  *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * See Error Description                                        *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * Upgrade to Informix Server 12.10.xC15 or 14.10.xC7 (when     *
    * available).                                                  *
    ****************************************************************
    

Problem conclusion

  • Fixed in Informix Server 12.10.xC15 and 14.10.xC7.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT35563

  • Reported component name

    INFORMIX SERVER

  • Reported component ID

    5725A3900

  • Reported release

    C10

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2021-01-18

  • Closed date

    2021-08-25

  • Last modified date

    2021-08-25

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    INFORMIX SERVER

  • Fixed component ID

    5725A3900

Applicable component levels

[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU053","label":"Cloud \u0026 Data Platform"},"Product":{"code":"SSGU8G","label":"Informix Servers"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"C10"}]

Document Information

Modified date: