IBM Support

IT34335: CANNOT PROBE HITACHI VSP F700 ARRAYS. PROBES END WITH ERROR HWN025032E.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Scenario exist as no pools are defined causing probes to
    fail.
    
    Because user had not created any pools, they were
    directly assigning LDEVs they had created from parity groups
    instead of the typical method of assigning those LDEVs to a
    dynamic pool and then creating LDEVs from the pool.
    
    Errors in
    Trace Logs:
    
    2020-09-16 14:20:41.572 - ERROR - HWN025032E Job
    failed during post processing of collected data from the data
    source.
    2020-09-16 14:20:41.572 - ERROR - Error processing data
    files. Exiting...
    2020-09-16 14:20:41.572 - DEBUG - Traceback
    (most recent call last):
     File "hitachi_vsp.py", line 271, in
    main
     File "Reporter.py", line 92, in start
     File
    "Reporter.py", line 1516, in probe
    KeyError:
    'host_connection_set'
    
    2020-09-16 14:20:41.572 - DEBUG -
    Writing status file...
    2020-09-16 14:20:41.572 - DEBUG - Exit
    code:
    99
    ____________________________________________________
    DB2
    Version used for Server: N/A
    The defect is against component:
    Storage
    Server/Manager build/release (TPC): 5.4.0
    Agent
    build/release (TPC): N/A
    Server/Manager (OS): N/A
    Agent(OS):  N/
    A
    ____________________________________________________
    Problem
    as described by customer:
    Cannot Probe Hitachi devices
    Initial
    customer impact (low/med/high): low
    

Local fix

  • TBD
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * IBM Spectrum Control & Storage Insights users monitoring     *
    * HITACHI VSP F700 where no pools are defined                  *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * Spectrum Control & Storage Insights users monitoring         *
    * HITACHI VSP F700 where no pools are defined are              *
    * experiencing failed probes.                                  *
    *                                                              *
    * Because the device did not have any pools, they were         *
    * configured by directly assigning LDEVs they had created      *
    * from parity groups instead of the typical method of          *
    * assigning those LDEVs to a dynamic pool and then             *
    * creating LDEVs from the pool.                                *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • The fix for this APAR is targeted for the following release:
    
    IBM Spectrum Control 5.4.2   [ 5.4.2-IBM-SC ]
    
    ( release target 1Q 2021 / February )
    
    http://www.ibm.com/support/docview.wss?&uid=swg21320822
    
    The target dates for future releases do not represent a formal
    commitment by IBM. The dates are subject to change without
    notice.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT34335

  • Reported component name

    TPC ADVANCED

  • Reported component ID

    5608TPCA0

  • Reported release

    540

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2020-09-23

  • Closed date

    2021-01-08

  • Last modified date

    2021-01-08

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TPC ADVANCED

  • Fixed component ID

    5608TPCA0

Applicable component levels

[{"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSNECY","label":"Tivoli Storage Productivity Center Advanced"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"540"}]

Document Information

Modified date:
25 June 2022