  • Closed as suggestion for future release.

Error description

  • Both replcheck_stat_tab and replcheck_stat_node_tab tables, in
    syscdr database, are operating with regular integer types for
    various row counts, so would be confused with any larger table
    holding more than 2 billion rows.
    
    As a consequence, the progress indicator and any row counts
    reported in 'cdr stats check --verbose' and 'cdr stats sync
    --verbose' can be way off, including the estimated "Remaining"
    time printed at the end of a task's output.
    

Local fix

Problem summary

Problem conclusion

Temporary fix

Comments

  • Defect will be addressed in future releases.
    