A fix is available
APAR status
-
Closed as program error.
Error description
-
Affected are users of DataPower using RBM and the API Connect Gateway Service in v5c mode. If RBM is configured it might cause the Gateway service to go down due to RBM blocking permissions for the hidden user which creates the Config on DataPower via the SOMA interface.
Local fix
-
Enable all local users as fallback users.
Problem summary
-
Affected are the users of DataPower using RBM and the API Connect Gateway Service in v5c mode. When RBM is configured, it might cause the Gateway service to go down due to RBM blocking permissions for the hidden user which creates the Config on DataPower via the SOMA interface.
Problem conclusion
-
Fix is available in 2018.4.1.8 For a list of the latest fix packs available, please see: http://www-01.ibm.com/support/docview.wss?uid=swg21237631
Temporary fix
-
Enable all local users as fallback users.
Comments
APAR Information
-
APAR number
IT30271
-
Reported component name
DATAPOWER
-
Reported component ID
DP1234567
-
Reported release
18X
-
Status
CLOSED PER
-
PE
NoPE
-
HIPER
NoHIPER
-
Special Attention
NoSpecatt / Xsystem
-
Submitted date
2019-09-12
-
Closed date
2019-10-14
-
Last modified date
2019-10-17
-
APAR is sysrouted FROM one or more of the following:
-
APAR is sysrouted TO one or more of the following:
Fix information
-
Fixed component name
DATAPOWER
-
Fixed component ID
DP1234567
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateway"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
08 June 2021