APAR status
Closed as program error.
Error description
When a Connect Direct Node transfers record of type PRED ("Process ended"), from Z/os to Linux then the CDInput Node fails with the error "BIP7974W" as the record does not contain "any relevant transfer/file metadata". The user may see the following error: BIP7974W: Received statistic from IBM Sterling Connect:Direct for file '', which does not specify a directory.
Local fix
Problem summary
**************************************************************** USERS AFFECTED: All users of IBM Integration Bus v10.0 and <span style="background-color:rgb(255, 255, 255)">AppConnect Enterprise V11.0 with CDInput node.</span> Platforms affected: z/OS, MultiPlatform **************************************************************** PROBLEM DESCRIPTION: When a CDInput node transfers record of type PRED ("Process ended"), it may fail with the error "BIP7974W" BIP7974W: Received statistic from IBM Sterling Connect:Direct for file '', which does not specify a directory. This issue is reported in a scenario where the product(IIB) is running on Linux and CD server is on z/OS
Problem conclusion
The product no longer fails when transferring a record of type PRED through CDIinput node. --------------------------------------------------------------- The fix is targeted for delivery in the following PTFs: Version Maintenance Level v10.0 10.0.0.19 v11.0 11.0.0.9 The latest available maintenance can be obtained from: http://www-01.ibm.com/support/docview.wss?rs=849&uid=swg27006041 If the maintenance level is not yet available,information on its planned availability can be found on: http://www-1.ibm.com/support/docview.wss?rs=849&uid=swg27006308 ---------------------------------------------------------------
Temporary fix
Comments
APAR Information
APAR number
IT30055
Reported component name
INTEGRATION BUS
Reported component ID
5724J0540
Reported release
A00
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2019-08-21
Closed date
2020-04-17
Last modified date
2020-05-20
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
INTEGRATION BUS
Fixed component ID
5724J0540
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSNQK6","label":"IBM Integration Bus"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
21 May 2020