Error description
When enabling SQLTRACES, it is then possible to view the SQL statements that have been run in "onstat -g his". If there are U/D/I triggers on a table that run SPL's then it is not easy to see the trigger / SPL especially on a busy system with lots of users as the statements can be far apart. Here are a few examples â ¦ Statement # 350: @ 700000020fc0b30 Statement text: Compiled Statement Statement information: Sess_id User_id Stmt Type Finish Time Run Time TX Stamp PDQ 407 1002 EXEC PROCEDURE 16:22:06 0.0002 1f8a03ab 0 Statement # 349: @ 700000020fc0b28 Procedure Call Stack: ts002495910:rob1_spl1() UPDATE using table [ state ] Statement information: Sess_id User_id Stmt Type Finish Time Run Time TX Stamp PDQ 407 1002 UPDATE 16:22:06 0.0001 1f8a03ab 0 and Statement # 368: @ 700000020fc0bc0 Statement text: Compiled Statement UPDATE using table [ rob2 ] Statement information: Sess_id User_id Stmt Type Finish Time Run Time TX Stamp PDQ 407 1002 UPDATE 16:27:27 0.0000 1f8a04db 0 Statement # 367: @ 700000020fc0bb8 Statement text: Compiled Statement Statement information: Sess_id User_id Stmt Type Finish Time Run Time TX Stamp PDQ 407 1002 EXEC PROCEDURE 16:27:27 0.0001 1f8a04db 0
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * Users of Informix Server prior to 12.10.xC14 and 14.10.xC4. * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Update to Informix Server 12.10.xC14 or 14.10.xC4 (when * * available). * ****************************************************************
Problem conclusion
Fixed in Informix Server 12.10.xC14 and 14.10.xC4.
Temporary fix
Comments
APAR Information
APAR number
IT30035
Reported component name
INFORMIX SERVER
Reported component ID
5725A3900
Reported release
C10
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2019-08-19
Closed date
2020-03-03
Last modified date
2020-03-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
INFORMIX SERVER
Fixed component ID
5725A3900
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSGU8G","label":"Informix Servers"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"C10","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
03 March 2020