IBM Support

IT29934: ALERTS GENERATED FOR "STORAGE SYSTEM NEW NODE" AFTER EACH PROBE EVEN THOUGH THERE ARE NO NEW NODES

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • "Storage System New Node" alerts are logged after each probe
    even though there are no new nodes in the environment.   This
    issue occurs when a New Entity alert (in this case, "Storage
    System New Node" alert) is created under an alert policy before
    a device is added as a member resource of the policy.
    

Local fix

  • Now that the device is already added as a member resource of the
    policy, we can work around the issue by re-creating the "Storage
    System New Node" alert:
    	1. Under the alert policy -> click "Edit Alert Definitions" ->
    click "-" sign to remove the "New Node" alert -> click "Save
    changes"
    	2. Click "Cancel" to go back to the table list view and confirm
    that "Storage System New Node" alert is indeed removed
    	3. Click "Edit Alert Definitions" -> Configure "New Node" alert
    again -> click "Save changes"
    	4. "Storage System New Node" alert should stop triggering
    starting from the next probe.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * IBM Storage Insights users with alerts for "Storage System   *
    * New Node"                                                    *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * "Storage System New Node" alerts are logged after each probe *
    * even though there are no new nodes in the environment.       *
    * This                                                         *
    * issue occurs when a New Entity alert (in this case, "Storage *
    * System New Node" alert) is created under an alert policy     *
    * before                                                       *
    * a device is added as a member resource of the policy.        *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • The fix for this APAR is targeted for the following release:
    
    IBM Storage Insights 1Q20   [ 5.3.6-IBM-SC ]
    
    ( release target February 1Q 2020 )
    
    The target dates for future releases do not represent a formal
    commitment by IBM. The dates are subject to change without
    notice.
    

Temporary fix

  • After a device is added as a member resource of the policy,
    you can work around the issue by re-creating the "Storage
    System New Node" alert:
    
    1. Under the alert policy -> click "Edit Alert Definitions" ->
    click "-" sign to remove the "New Node" alert -> click "Save
    changes"
    
    2. Click "Cancel" to go back to the table list view and confirm
    that "Storage System New Node" alert is indeed removed
    
    3. Click "Edit Alert Definitions" -> Configure "New Node" alert
    again -> click "Save changes"
    
    4. "Storage System New Node" alert should stop triggering
    starting from the next probe.
    

Comments

APAR Information

  • APAR number

    IT29934

  • Reported component name

    STORAGE INSIGHT

  • Reported component ID

    5608TPCSI

  • Reported release

    533

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2019-08-07

  • Closed date

    2019-09-06

  • Last modified date

    2020-01-27

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    STORAGE INSIGHT

  • Fixed component ID

    5608TPCSI

Applicable component levels

  • R533 PSY

       UP

[{"Line of Business":{"code":"LOB26","label":"Storage"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSQRB8","label":"IBM Storage Insights"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"533"}]

Document Information

Modified date:
08 February 2022