IBM Support

IT28232: ALERTS FOR PROBE FAILURES SEEN BY CUSTOMER; NO FAILED PROBE APPARENT IN THE LOGS OR GUI

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • Alerts for probe failures seen by customer; no failed probe
    apparent in the logs or GUI
    
    DETAIL OF PROBLEM:
    IBM Storage Insights is capable of sending alerts for failed
    monitoring tasks to end-users; in certain situations these
    alerts are being sent to users, when there is no failed probe
    task visible in the GUI.
    
    The cause of these misleading alerts being sent is when a probe
    is started, while an existing probe of the same device is
    already in progress.  The failure messaging about the probe
    already in progress is intentionally not displayed in the
    Storage Insights GUI by design; the alerts for these jobs
    however was not disabled.
    
    This APAR will disable alerting for jobs that fail due to a
    previous job still running for the same device, thus avoiding
    unnecessary customer alerting.
    
    
    RECREATE STEPS:  N/A
    ________________________________________________________________
    
    ________________________________________________________________
    Problem as described by customer:  	SI Generating Probe Status
    Errors for Arrays But In Probe Logs there is no error shown
    Initial customer impact (low/med/high): low
    

Local fix

  • Local Fix:  N/A.  Fix coming in future Storage Insights upgrade.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * IBM Storage Insights users probing storage devices           *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * IBM Storage Insights is capable of sending alerts for failed *
    * monitoring tasks to end-users.  In rare situations these     *
    * alerts are being sent to users when there is no failed probe *
    * task visible in the GUI.                                     *
    *                                                              *
    * The probes are the cause of these misleading alerts:         *
    * if a probe is started while an existing probe of the same    *
    * device is already in progress.                               *
    *                                                              *
    * The failure messaging about the probe already in progress    *
    * was intentionally not displayed in the Storage Insights GUI  *
    * by design. However, the alerts for these job failures were   *
    * not disabled.                                                *
    *                                                              *
    * This APAR disables alerting for jobs that fail due to a      *
    * previous job still running for the same device, thus         *
    * avoiding unnecessary customer alerting.                      *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • The fix for this APAR is targeted for the following release:
    
    IBM Storage Insights 4Q19   [ 5.3.5-IBM-SC ]
    
    ( release target November 4Q 2019 )
    
    The target dates for future releases do not represent a formal
    commitment by IBM. The dates are subject to change without
    notice.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT28232

  • Reported component name

    STORAGE INSIGHT

  • Reported component ID

    5608TPCSI

  • Reported release

    100

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2019-02-26

  • Closed date

    2019-10-15

  • Last modified date

    2019-10-15

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    STORAGE INSIGHT

  • Fixed component ID

    5608TPCSI

Applicable component levels

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSQRB8","label":"IBM Storage Insights"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"100","Edition":"","Line of Business":{"code":"LOB26","label":"Storage"}}]

Document Information

Modified date:
08 February 2022