APAR status
Closed as program error.
Error description
A limitation of 'standard mode' is that you can only have one you can only have one Integration Server (Execution Group) per Integration Node (Broker). If a user should attempt to create another Integration Server using the mqsicreateexecutiongroup command it fails, which is the correct behavior, but it presents a incorrect and misleading error message, thus :- BIP1920S: The integration node 'test_broker' cannot be reached. Check that the integration node is running, and that the HTTP listener for the web administration port is running. BIP8081E: An error occurred while processing the command. An error occurred while the command was running; the command has cleaned up and ended. Use messages prior to this one to determine the cause of the error. Check for some common problems: Does the user id have the correct authorities (for example a member of the mqbrkrs group)? Is any operating system limit set too low to allow the command to run? Is the environment correctly set up? Correct the problem and retry the command, otherwise, contact your IBM support center. The code has been changed to present the correct BIP1825E message. Additional Symptom(s) Search Keyword(s):
Local fix
NA
Problem summary
**************************************************************** USERS AFFECTED: All users of App Connect Enterprise v11 running the mqsicreateexecutiongroup command when in 'Standard Mode' Platforms affected: MultiPlatform **************************************************************** PROBLEM DESCRIPTION: A limitation of 'standard mode' is that you can only have one Integration Server (Execution Group) per Integration Node (Broker). If a user should attempt to create another Integration Server using the mqsicreateexecutiongroup command it fails, which is the correct behavior, but it presents an incorrect and misleading error message, thus :- BIP1920S: The integration node 'test_broker' cannot be reached. Check that the integration node is running, and that the HTTP listener for the web administration port is running. BIP8081E: An error occurred while processing the command. An error occurred while the command was running; the command has cleaned up and ended. Use messages prior to this one to determine the cause of the error. Check for some common problems: Does the user id have the correct authorities (for example a member of the mqbrkrs group)? Is any operating system limit set too low to allow the command to run? Is the environment correctly set up? Correct the problem and retry the command, otherwise, contact your IBM support center. The code has been changed in order to present the correct BIP1825E message.
Problem conclusion
The product now presents the correct BIP1825E message. --------------------------------------------------------------- The fix is targeted for delivery in the following PTFs: Version Maintenance Level v11.0 11.0.0.4 The latest available maintenance can be obtained from: http://www-01.ibm.com/support/docview.wss?rs=849&uid=swg27006041 If the maintenance level is not yet available,information on its planned availability can be found on: http://www-1.ibm.com/support/docview.wss?rs=849&uid=swg27006308 ---------------------------------------------------------------
Temporary fix
Comments
APAR Information
APAR number
IT28167
Reported component name
APP CONNECT ENT
Reported component ID
5724J0550
Reported release
B00
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2019-02-19
Closed date
2019-05-13
Last modified date
2019-05-13
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
APP CONNECT ENT
Fixed component ID
5724J0550
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSDR5J","label":"IBM App Connect Enterprise"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"B00","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date: