A fix is available
APAR status
Closed as program error.
Error description
OAuth security objects in the API Gateway can be configured with no scopes however this needs to create the object in a downed state instead of blocking the object all together. This change removes the scope requirement.
Local fix
Problem summary
API Security OAuth and API Security OAuth Requirement management objects could be operational without a configured scope.
Problem conclusion
Fix is available in 2018.4.1.3. For a list of the latest fix packs available, please see: http://www-01.ibm.com/support/docview.wss?uid=swg21237631
Temporary fix
Comments
APAR Information
APAR number
IT28081
Reported component name
DATAPOWER
Reported component ID
DP1234567
Reported release
760
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2019-02-19
Closed date
2019-02-26
Last modified date
2019-02-26
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
DATAPOWER
Fixed component ID
DP1234567
Applicable component levels
R770 PSY
UP
[{"Line of Business":{"code":"LOB45","label":"Automation"},"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateways"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"760"}]