IBM Support

IT26803: UNABLE TO SET SCHEDULED REPORT RUN TIME AFTER UPGRADING TO VERSION 10.1.2

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • After upgrading to IBM Spectrum Protect Plus 10.1.2, you can no
    longer
    configure the start time for a scheduled report to be sent.
    MDVREGR
    Steps to recreate:
    - Using 10.1.1.X, configure a Scheduled report.
     Report -> Choose report -> Select "Define Schedule" -> Input
    schedule start time.
    - Upgrade to 10.1.2.
    After the upgrade, the option to set the schedule run time is
    not available.
    Keywords: frequency TS001521014
    Versions affected: 10.1.2.X
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * IBM Spectrum Protect Plus levels 10.1.2.                     *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * See Error Description                                        *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * Apply fixing level when available. This problem is currently *
    * projected to be fixed in IBM Spectrum Protect Plus level     *
    * 10.1.2.209, 10.1.3.  Note that this is subject to change at  *
    * the discretion of IBM.                                       *
    ****************************************************************
    

Problem conclusion

  • IBM Spectrum Protect Plus has been updated to resolve an issue
    where the GUI hides the schedule start form fields for customers
    who have upgraded to 10.1.2.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT26803

  • Reported component name

    SP PLUS

  • Reported component ID

    5737SPLUS

  • Reported release

    A12

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2018-10-29

  • Closed date

    2018-11-15

  • Last modified date

    2018-11-15

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    SP PLUS

  • Fixed component ID

    5737SPLUS

Applicable component levels

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSNQFQ","label":"IBM Spectrum Protect Plus"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"A12","Line of Business":{"code":"LOB26","label":"Storage"}}]