IT26104: INCOMPATIBLE GSKIT VERSIONS CAUSE OPERATION FAILURES IN IBM SPECTRUM PROTECT WITH RC30

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as documentation error.

Error description

  • In environments where different versions of GSKit are installed,
    the IBM Spectrum Protect Backup/Archive client and API will
    report operation failures.  Failures are reported when other
    applications deliver a GSKit version which is newer than the
    version delivered with IBM Spectrum Protect.
    
    Customer/L2 Diagnostics:
    In situations where this problem occurs, backups can report a
    Return Code 30, and something similar to the following will be
    seen in a service trace:
    GSKKMlib::psLoadFunctions(): LoadGSKitLibrary() failed for file
    'gsk8km_64.dll': rc = 127
    GSKitPasswordFile::GSKitPasswordFile:psLoadFunctions failed with
    error 5802
    
    Versions Affected:
    Backup-Archive Clients 7.1.8, and 8.1.2 and higher on all
    Supported platforms
    
    Initial Impact: Low
    
    Additional Keywords: TSM, IBM Spectrum Protect, TSM,DB2API, gsk8
    

Local fix

  • Use the instructions in the guide to create a symbolic link if
    the GSKit supplied with the Backup-Archive Client is newer than
    the other application's GSKit.  If the other application's GSKIt
     is newer than the GSKit supplied by the Backup-Archive Client,
    then the REVERSE of the instructions in the guide will be
    required to resolve the issue (create a symbolic link in the IBM
     Spectrum Protect Client's gskit directory to point to the path
    of the newer GSKit).
    https://www.ibm.com/support/knowledgecenter/SSEQVQ_8.1.4/client/
    t_cfg_ssl_symb_lnk_gskit.html
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * IBM Spectrum Protect Backup-Archive Client versions 7.1.8,   *
    * and 8.1.2, 8.1.4, 8.1.6  and 8.1.7 on all platforms.         *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * See ERROR DESCRIPTION.                                       *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * Apply fixing level when available. This issue is projected   *
    * to be fixed in the 8.1.8 update to the IBM Spectrum Protect  *
    * Backup-Archive Clients Installation and User's Guide.        *
    *                                                              *
    * Until this information is published, the associated          *
    * information updates are documented in the V8.1 Documentation *
    * Updates tech note located here:                              *
    *     Windows -                                                *
    * http://www.ibm.com/support/docview.wss?uid=swg27048956       *
    *     UNIX and Llinux -                                        *
    * http://www.ibm.com/support/docview.wss?uid=swg27048955       *
    *                                                              *
    * You can locate the entry associated with this APAR by using  *
    * the APAR number as a keyword to search the document.         *
    *                                                              *
    * Note: This information is subject to change at the           *
    * discretion of IBM.                                           *
    ****************************************************************
    

Problem conclusion

  • The corrected information will be published with the IBM
    Spectrum Protect Backup-Archive Clients 8.1.8 documentation and
    included in the V8.1 Documentation Updates tech note. The
    updates will be reflected in the procedure steps of the topic
    titled as: Creating a symbolic link to access the latest GSKit
    library.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT26104

  • Reported component name

    TSM CLIENT

  • Reported component ID

    5698ISMCL

  • Reported release

    81A

  • Status

    CLOSED DOC

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2018-09-10

  • Closed date

    2019-04-05

  • Last modified date

    2019-04-05

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGSG7","label":"Tivoli Storage Manager"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"81A","Edition":"","Line of Business":{"code":"LOB26","label":"Storage"}}]

Document Information

Modified date:
05 April 2019