APAR status
Closed as program error.
Error description
In cases where an input connector creates Event objects but then does not pass them to the deliverEvents() call, the objects will never be garbage-collected due to a C++ global reference having been created during Event construction. This fix moves the creation of global references to the deliverEvents() call, allowing undelivered events to be garbage-collected.
Local fix
Problem summary
**************************************************************** USERS AFFECTED: All users of IBM Integration Bus V10 and App Connect Enterprise V11 with a user-provided Input Connector Platforms affected: MultiPlatform, z/OS **************************************************************** PROBLEM DESCRIPTION: In cases where an input connector creates Event objects but then does not pass them to the deliverEvents() call, the objects will never be garbage-collected due to a C++ global reference having been created during Event construction.
Problem conclusion
This fix moves the creation of global references to the deliverEvents() call, allowing undelivered events to be garbage-collected. --------------------------------------------------------------- The fix is targeted for delivery in the following PTFs: Version Maintenance Level v10.0 10.0.0.15 v11.0 11.0.0.2 The latest available maintenance can be obtained from: http://www-01.ibm.com/support/docview.wss?rs=849&uid=swg27006041 If the maintenance level is not yet available,information on its planned availability can be found on: http://www-1.ibm.com/support/docview.wss?rs=849&uid=swg27006308 ---------------------------------------------------------------
Temporary fix
Comments
APAR Information
APAR number
IT26016
Reported component name
INTEGRATION BUS
Reported component ID
5724J0540
Reported release
A00
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-08-20
Closed date
2018-10-11
Last modified date
2018-10-11
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
INTEGRATION BUS
Fixed component ID
5724J0540
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSNQK6","label":"IBM Integration Bus"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"10.0","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
11 October 2018