IBM Support

IT24608: INTEGRATION SERVER ABENDS WHEN WLM ENABLED AND ADDITIONAL INSTANCES SET

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • When a message flow is deployed with the Workload Management
    (WLM) property processingTimeoutSec set to a value greater than
    zero and additional instances for the flow is also greater than
    zero, the integration server may abend when the message flow is
    run under heavy load.
    
    The abend stacks may not all be consistent, but some may be
    similar to the following:
    
    malloc_buckets []
    prime_pool_mt []
    <no name available> (libicuuc.so)
    <no name available> (libicuuc.so)
    <no name available> (libicuuc.so)
    <no name available> (libicuuc.so)
    __ct__15ImbConverterCPPFUii (libCommonServices.a.so)
    __ct__10ImbMqCharvFRC10ImbWstringi (libMessageServices.a.so)
    putToTopic__11ImbMqHelperFRC9ImbBufferbPCciT4
    (libMessageServices.a.so)
    publishMonitoringEventXMLMessage__20ImbWlmEventWriterXMLFP16ImbT
    hreadContextR9ImbBufferRC10ImbWstringbN24
    (libMessageServices.a.so)
    writeMonitoringEventXML__20ImbWlmEventWriterXMLFRC18ImbMonitorin
    gEventb10ImbWstring (libMessageServices.a.so)
    publishNotificationEvent__18ImbWlmActionCurfewFRC10ImbWstringlT2
    T1 (libMessageServices.a.so)
    comingIn__19ImbWlmThreadContextFv (libMessageServices.a.so)
    comingIn__18ImbWlmActionCurfewFv (libMessageServices.a.so)
    endGathering__14ImbWlmGathererFRC15ImbDataFlowNode
    (libMessageServices.a.so)
    run__18ImbCommonInputNodeFP11ImbOsThread (libMQLibrary.a.so)
    
    malloc_buckets []
    malloc_common@AF103_86 []
    _Fancy_malloc__FUl [/usr/lib/libC.a(ansicore_64.o)]
    init_pres__FUl [/usr/lib/libC.a(ansicore_64.o)]
    getSMFTFromPool__19ImbDataFlowSMFTPoolFRC15ImbDataFlowNode
    (libMessageServices.a.so)
    getNewSmftFromSet__13ImbWlmSMFTSetFRC15ImbDataFlowNode7ImbDate7I
    mbTime (libMessageServices.a.so)
    startInputNodeStats__14ImbWlmGathererFRC15ImbDataFlowNode
    (libMessageServices.a.so)
    startGathering__14ImbWlmGathererFRC15ImbDataFlowNodei
    (libMessageServices.a.so)
    run__18ImbCommonInputNodeFP11ImbOsThread (libMQLibrary.a.so)
    
    
    free_buckets [ ]
    free_common [ ]
    <no name available> (libicuuc.so)
    <no name available> (libicuuc.so)
    __dt__15ImbConverterCPPFv (libCommonServices.a.so)
    publishNotificationEvent__18ImbWlmActionCurfewFRC10ImbWstringlT2
    T1 (libMessageServices.a.so)
    comingIn__19ImbWlmThreadContextFv (libMessageServices.a.so)
    comingIn__18ImbWlmActionCurfewFv (libMessageServices.a.so)
    endGathering__14ImbWlmGathererFRC15ImbDataFlowNode
    (libMessageServices.a.so)
    run__18ImbCommonInputNodeFP11ImbOsThread (libMQLibrary.a.so)
    
    Additional Symptom(s) Search Keyword(s):WLM, TimeoutSec,
    ADDITIONAL INSTANCES
    

Local fix

Problem summary

  • ****************************************************************
    USERS AFFECTED:
    All users of IBM Integration Bus v9 and v10 and IBM App Connect
    Enterprise v11 who are using Workload Management (WLM).
    
    
    Platforms affected:
    z/OS, MultiPlatform
    
    ****************************************************************
    PROBLEM DESCRIPTION:
    When a message flow is deployed with the Workload Management
    (WLM) property processingTimeoutSec set to a value greater than
    zero and additional instances for the flow is also greater than
    zero, the integration server might abend when the message flow
    is run under heavy load.
    
    The abend stacks may not all be consistent, but some may be
    similar to the following:
    
    malloc_buckets []
    prime_pool_mt []
    <no name available> (libicuuc.so)
    <no name available> (libicuuc.so)
    <no name available> (libicuuc.so)
    <no name available> (libicuuc.so)
    __ct__15ImbConverterCPPFUii (libCommonServices.a.so)
    __ct__10ImbMqCharvFRC10ImbWstringi (libMessageServices.a.so)
    putToTopic__11ImbMqHelperFRC9ImbBufferbPCciT4
    (libMessageServices.a.so)
    publishMonitoringEventXMLMessage__20ImbWlmEventWriterXMLFP16ImbT
    hreadContextR9ImbBufferRC10ImbWstringbN24
    (libMessageServices.a.so)
    writeMonitoringEventXML__20ImbWlmEventWriterXMLFRC18ImbMonitorin
    gEventb10ImbWstring (libMessageServices.a.so)
    publishNotificationEvent__18ImbWlmActionCurfewFRC10ImbWstringlT2
    T1 (libMessageServices.a.so)
    comingIn__19ImbWlmThreadContextFv (libMessageServices.a.so)
    comingIn__18ImbWlmActionCurfewFv (libMessageServices.a.so)
    endGathering__14ImbWlmGathererFRC15ImbDataFlowNode
    (libMessageServices.a.so)
    run__18ImbCommonInputNodeFP11ImbOsThread (libMQLibrary.a.so)
    
    malloc_buckets []
    malloc_common@AF103_86 []
    _Fancy_malloc__FUl [/usr/lib/libC.a(ansicore_64.o)]
    init_pres__FUl [/usr/lib/libC.a(ansicore_64.o)]
    getSMFTFromPool__19ImbDataFlowSMFTPoolFRC15ImbDataFlowNode
    (libMessageServices.a.so)
    getNewSmftFromSet__13ImbWlmSMFTSetFRC15ImbDataFlowNode7ImbDate7I
    mbTime (libMessageServices.a.so)
    startInputNodeStats__14ImbWlmGathererFRC15ImbDataFlowNode
    (libMessageServices.a.so)
    startGathering__14ImbWlmGathererFRC15ImbDataFlowNodei
    (libMessageServices.a.so)
    run__18ImbCommonInputNodeFP11ImbOsThread (libMQLibrary.a.so)
    
    
    free_buckets [ ]
    free_common [ ]
    <no name available> (libicuuc.so)
    <no name available> (libicuuc.so)
    __dt__15ImbConverterCPPFv (libCommonServices.a.so)
    publishNotificationEvent__18ImbWlmActionCurfewFRC10ImbWstringlT2
    T1 (libMessageServices.a.so)
    comingIn__19ImbWlmThreadContextFv (libMessageServices.a.so)
    comingIn__18ImbWlmActionCurfewFv (libMessageServices.a.so)
    endGathering__14ImbWlmGathererFRC15ImbDataFlowNode
    (libMessageServices.a.so)
    run__18ImbCommonInputNodeFP11ImbOsThread (libMQLibrary.a.so)
    

Problem conclusion

  • The product no longer abends when multiple threads for the same
    message flow attempt to publish WLM notification events.
    
    ---------------------------------------------------------------
    The fix is targeted for delivery in the following PTFs:
    
    Version    Maintenance Level
    v10.0      10.0.0.16
    v11.0      11.0.0.4
    v9.0       9.0.0.11
    
    The latest available maintenance can be obtained from:
    http://www-01.ibm.com/support/docview.wss?rs=849&uid=swg27006041
    
    If the maintenance level is not yet available,information on
    its planned availability can be found on:
    http://www-1.ibm.com/support/docview.wss?rs=849&uid=swg27006308
    ---------------------------------------------------------------
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT24608

  • Reported component name

    INTEGRATION BUS

  • Reported component ID

    5724J0530

  • Reported release

    900

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2018-04-04

  • Closed date

    2019-04-17

  • Last modified date

    2019-04-17

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    INTEGRATION BUS

  • Fixed component ID

    5724J0530

Applicable component levels

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSNQK6","label":"IBM Integration Bus"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"9.0","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date: