A fix is available
APAR status
Closed as program error.
Error description
Brocade switch probes fail with HWN021899E Switch has not associated fabric. The error is caused by entries in the database associating a particular switch with multiple fabrics due to principal switch changes in the fabric that were not processed correctly. The switch doesn't actually belong to both fabrics at the same time and the incorrect association causes the probe to fail. Principal switch changes can occur with fabrics and should be handled such that Spectrum Control has the correct switch and fabric relationships to continue probing. fabric probe log 2017-09-28 08:24:09.934 BTAFM0614I The probe task is to probe topology and zone. The probe algorithm is CIM association. 2017-09-28 08:24:10.012 BTAFM5003E Requests to an SMI agent did not correctly collect a set of switches for fabric <fabric_WWN>. 2017-09-28 08:24:10.012 BTAFM5002E The SMI agents <agent_IP> returned an error or can no longer contact the switches. 2017-09-28 08:24:12.949 BTADS0102E The data can't be collected by the probe because the data collector or the storage resource that is being probed isn't available. The run ID for the probe is 34035, the job ID is 104066, the status of the process is 4, and the return code is 1 . traceTPCDeviceServer.log HWN099993E HWN021899E @(Process Processor (Thread-7429)) com.ibm.tpc.common.api.TPCServerException: HWN021899E Switch <switch_WWN> has no associated Fabric. at com.ibm.tpc.disk.common.util.DiskMessageHelper.getTPCServerExcep tion(DiskMessageHelper.java:209) at com.ibm.tpc.disk.discovery.FabricGenericDiscoveryProcessPlugin.c heckAllSwitchesInFabricOrNPV(FabricGenericDiscoveryProcessPlugin .java:1305) at com.ibm.tpc.disk.discovery.FabricGenericDiscoveryProcessPlugin.c ollectDeviceData(FabricGenericDiscoveryProcessPlugin.java:246) at com.ibm.tpc.disk.discovery.TopLevelDiscoveryProcess.collectDevic es(TopLevelDiscoveryProcess.java:538) at com.ibm.tpc.disk.discovery.TopLevelDiscoveryProcess.process(TopL evelDiscoveryProcess.java:676) at com.ibm.tpc.Router.perform(Router.java:706) at com.ibm.tpc.Router.perform(Router.java:445) at com.ibm.tpc.discovery.ProcessProcessor.process(ProcessProcessor. java:78) at com.ibm.tpc.infrastructure.threads.TPCThread.run(TPCThread.java: 253) com.ibm.tpc.disk.discovery.FabricGenericDiscoveryProcessPlugin checkAllSwitchesInFabricOrNPV
Local fix
Contact IBM support for assistance cleaning up invalid entries from the Spectrum Control database.
Problem summary
**************************************************************** * USERS AFFECTED: * * IBM Spectrum Control 5.2.x users monitoring and managing * * Brocade Fabrics. * **************************************************************** * PROBLEM DESCRIPTION: * * Sometimes, when the connection from Spectrum Control Server * * to BNA CIMOM fails and there are multiple CIMOMs used, the * * database data might become inconsistent, regarding Fabric to * * Switch relations. * **************************************************************** * RECOMMENDATION: * * Apply fix maintenance when available * **************************************************************** This fix adds a cleanup procedure that should resolve the issue. This is a 2 step procedure and the cleanup is done when running the Fabric probe the first time, and the Fabric probe will fail. When the Fabric probe is ran the second time it should finish successfully.
Problem conclusion
The fix for this APAR is contained in the following maintenance package: IBM Spectrum Control 5.2.17 | refresh pack | 5.2-TIV-TPC-RP0017 | May 2018 http://www.ibm.com/support/docview.wss?&uid=swg21320822 The target dates for future releases do not represent a formal commitment by IBM. The dates are subject to change without notice.
Temporary fix
Comments
APAR Information
APAR number
IT23336
Reported component name
TPC ADVANCED
Reported component ID
5608TPCA0
Reported release
52E
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-11-29
Closed date
2018-04-17
Last modified date
2018-04-17
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TPC ADVANCED
Fixed component ID
5608TPCA0
Applicable component levels
[{"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSNECY","label":"Tivoli Storage Productivity Center Advanced"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"52E"}]
Document Information
Modified date: