APAR status
Closed as program error.
Error description
Monitoring Events (both terminal and Transaction Event Sources) are being emitted to millisecond precision, sometimes to microsecond precision.
Local fix
Problem summary
**************************************************************** USERS AFFECTED: All users of IBM Integration Bus V9.0/V10.0 and IBM App Connect Enterprise V11.0 using Monitoring Events (both terminal and Transaction Event Sources). Platforms affected: MultiPlatform, z/OS **************************************************************** PROBLEM DESCRIPTION: Monitoring Events (both terminal and Transaction Event Sources) are being emitted to millisecond precision, sometimes to microsecond precision.
Problem conclusion
The product allows the users to set the an environment variable called MQSI_TIME_MICRO_PRECISION which will consistently provide microsecond precision --------------------------------------------------------------- The fix is targeted for delivery in the following PTFs: Version Maintenance Level v10.0 10.0.0.14 v11.0 11.0.0.2 v9.0 9.0.0.11 The latest available maintenance can be obtained from: http://www-01.ibm.com/support/docview.wss?rs=849&uid=swg27006041 If the maintenance level is not yet available,information on its planned availability can be found on: http://www-1.ibm.com/support/docview.wss?rs=849&uid=swg27006308 ---------------------------------------------------------------
Temporary fix
Comments
APAR Information
APAR number
IT23096
Reported component name
INTEGRATION BUS
Reported component ID
5724J0530
Reported release
900
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-11-09
Closed date
2018-08-29
Last modified date
2018-08-29
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
INTEGRATION BUS
Fixed component ID
5724J0530
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSNQK6","label":"IBM Integration Bus"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"9.0","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date: