Fixes are available
APAR status
Closed as program error.
Error description
From the end user, after updating from PCOMM ver6.0.9 to ver12.0.2, it was pointed out that the order of cursor movement at the time of pressing the ENTER key (NewLine function) in some operation menu is different between before and after updating PCOMM.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * All IBM Personal Communications users of 5250 sessions * **************************************************************** * PROBLEM DESCRIPTION: * * After upgrading from PCOMM 6.0.9 to 12.0.2, the order of * * cursor movement when pressing the ENTER key (NewLine * * function) in some host application menu screens is * * different. * **************************************************************** * RECOMMENDATION: * **************************************************************** Steps to reproduce 1. Connect to 5250 host using IBM Personal Communication (PCOMM). 2. Navigate to the host screen which has 2 or more input/entry fields in multiple rows. 3. Set cursor position at first entry/input field in first row. 4. Input 'Newline'. 5. Cursor will move to next input/entry field in the same row, whereas cursor is supposed to move to next row. This issue is specific to first row only.
Problem conclusion
In this particular type of host screen, when two or more input/entry fields exist in the first row and if a user inputs 'Newline', the current implementation treats it like the field-exit key. PCSKTK52.DLL code changes have been made treat the input appropriately. Fix scheduled for PCOM 12.0.3.0 and 13.0.1.0 Refresh Pack.
Temporary fix
Comments
APAR Information
APAR number
IT22889
Reported component name
PCOMM COMBO-ENG
Reported component ID
5639I7000
Reported release
C00
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-10-23
Closed date
2017-11-15
Last modified date
2018-03-16
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
PCSKTK52
Fix information
Fixed component name
PCOMM COMBO-ENG
Fixed component ID
5639I7000
Applicable component levels
RC00 PSY
UP
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSEQ5Y","label":"Personal Communications"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"C00","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
16 March 2018