Direct links to fixes
APAR status
Closed as program error.
Error description
With this setting all WebUI queries will get blocked until the probes/events processing commit their changes. Newer version of DB2 have instead Currently Committed (CUR_COMMIT) = ON This means that the previously committed data will be returned and there is no blocking for the WebUI. The installer has to check if CUR_COMMIT is DISABLED and if it is then it will have to enable it ( DB2 9.7 ).
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * IBM Spectrum Control 5.2.x users upgrading to 5.2.13, * * 5.2.14, or 5.2.15 * **************************************************************** * PROBLEM DESCRIPTION: * * This setting impacts WebUI queries and may get blocked until * * the probes/events processing commit their changes have * * completed. * * Newer version of DB2 have instead * * Currently Committed (CUR_COMMIT) = ON * * * * This means that the previously committed data will be * * returned and there is no blocking for the WebUI. * * * * The installer has been updated to check if CUR_COMMIT is * * DISABLED and if it is then it will enable it * **************************************************************** * RECOMMENDATION: * * Apply fix maintenance when available * ****************************************************************
Problem conclusion
The fix for this APAR is contained in the following maintenance package: | refresh pack | 5.2-TIV-TPC-RP0016 | March 2018 http://www.ibm.com/support/docview.wss?&uid=swg21320822 The target dates for future releases do not represent a formal commitment by IBM. The dates are subject to change without notice.
Temporary fix
Comments
APAR Information
APAR number
IT22463
Reported component name
TPC ADVANCED
Reported component ID
5608TPCA0
Reported release
52D
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-09-20
Closed date
2017-12-06
Last modified date
2017-12-06
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TPC ADVANCED
Fixed component ID
5608TPCA0
Applicable component levels
[{"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSC6VJ","label":"IBM Spectrum Control Advanced Edition"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"52D"}]
Document Information
Modified date:
04 September 2023