Error description

  • If you create a bar file with a mixture of flows and subflows
    and use the compile in line option then any esql that is
    reference from by the flow and in a subflow will not have that
    ESQL included in the bar file. The flow will have it in lined.
    The esql file needs to be included if it referenced by a
    subflow since subflows are not in-lined.
    
    Additional Symptom(s) Search Keyword(s):
    

Local fix

  • Do not use the compile in line option when using subflows
    unless you have to. For example you have used a .msgflow as a
    subflow.
    

Problem summary

  • ****************************************************************
    USERS AFFECTED:
    All user of the IBM Integration Toolkit V10 building bar files
    and using the compile and in line option on the bar with a
    mixture of message flows and subflows.
    
    
    Platforms affected:
    Windows on x86-64 platform, Linux on x86-64 platform
    
    ****************************************************************
    PROBLEM DESCRIPTION:
    When building a bar file with the compile and in line option set
    , ESQL files are not included if referenced by the main flow.
    This will cause the deploy to fail of the esql referenced by the
    main flow is also referenced by  a subflow.
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    IT22429

  • Reported component name

    IIB TOOLKIT

  • Reported component ID

    5724J0541

  • Reported release

    A00

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2017-09-18

  • Closed date

    2017-11-28

  • Last modified date

    2017-11-28

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    IIB TOOLKIT

  • Fixed component ID

    5724J0541

Applicable component levels

  • RA00 PSY

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSNQK6","label":"IBM Integration Bus"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"10.0","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
28 November 2017