Error description

  • Integration servers, applications and libraries do not have a
    direct setting for whether the test record method is enabled or
    not. Instead these container objects will query all of the
    message flows within them to see if any flow is enabled for
    recording messages. If at least one flow is enabled then
    getTestRecordMode() will return Enabled. If not, then Disabled
    will be returned.
    
    A defect exists such that the value will return Disabled even
    if one flow within the container was Enabled.
    

Local fix

Problem summary

  • ****************************************************************
    USERS AFFECTED:
    All users of IBM Integration Bus v10.0 using the Integration
    API's getTestRecordMode() method on ExecutionGroupProxy,
    ApplicationProxy or LibraryProxy objects.
    
    
    Platforms affected:
    z/OS, MultiPlatform
    
    ****************************************************************
    PROBLEM DESCRIPTION:
    Integration servers, applications and libraries do not have a
    direct setting for whether the test record method is enabled or
    not. Instead these container objects will query all of the
    message flows within them to see if any flow is enabled for
    recording messages. If at least one flow is enabled then
    getTestRecordMode() will return Enabled. If not, then Disabled
    will be returned.
    
    A defect existed such that the value returned was Disabled even
    if one flow within the container was Enabled.
    

Problem conclusion

  • The product has been modified so that the Integration API's
    getTestRecordMode() now accurately reflects the state of the
    message flows within ExecutionGroupProxy, ApplicationProxy and
    LibraryProxy objects.
    
    ---------------------------------------------------------------
    The fix is targeted for delivery in the following PTFs:
    
    Version    Maintenance Level
    v10.0      10.0.0.11
    
    The latest available maintenance can be obtained from:
    http://www-01.ibm.com/support/docview.wss?rs=849&uid=swg27006041
    
    If the maintenance level is not yet available,information on
    its planned availability can be found on:
    http://www-1.ibm.com/support/docview.wss?rs=849&uid=swg27006308
    ---------------------------------------------------------------
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT20877

  • Reported component name

    INTEGRATION BUS

  • Reported component ID

    5724J0540

  • Reported release

    A00

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2017-06-05

  • Closed date

    2017-11-28

  • Last modified date

    2017-11-28

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    INTEGRATION BUS

  • Fixed component ID

    5724J0540

Applicable component levels

  • RA00 PSY

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSNQK6","label":"IBM Integration Bus"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"10.0","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
23 March 2020