IBM Support

IT20854: MAPPING NODE WARNINGS IN STDERR

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • After upgrading IBM Integration Bus fix pack, warnings may
    appear in the stderr of an Integration Server each time the
    Mapping node is
    invoked.
    
    This can happen when the flow has not been redeployed after the
    upgrade.
    
    An example of a warning is
    
    IXJXE0943E: [ERR 0754] Warning, the
    specified translet, 'xmap__............', was created using a
    version of the processor older than the version of the processor
    run-time that is in use. You may get performance benefits if you
    recompile the
    stylesheet or query with the newer version of the processor.
    

Local fix

  • Rebuild the BAR files and redeploy or delete all deployed flows
    and redeploy the BAR files without rebuilding them.
    

Problem summary

  • ****************************************************************
    USERS AFFECTED:
    Users of IBM Integration Bus versions 9 and 10, who use Mapping
    node and upgrade the Integration Bus fix pack without
    redeploying the BAR files.
    
    
    Platforms affected:
    MultiPlatform, z/OS
    
    ****************************************************************
    PROBLEM DESCRIPTION:
    After upgrading IBM Integration Bus fix pack, warnings may
    appear in the stderr of an Integration Server each time the
    Mapping node is
    invoked.
    
    This can happen when the flow has not been redeployed after the
    upgrade.
    
    An example of a warning is
    
    IXJXE0943E: [ERR 0754] Warning, the
    specified translet, 'xmap__............', was created using a
    version of the processor older than the version of the processor
    run-time that is in use. You may get performance benefits if you
    recompile the
    stylesheet or query with the newer version of the processor.
    
    The Mapping will operate correctly, however these messages will
    cause the integration server stderr file, within the location
    defined via MQSI_WORKPATH, to grow in size over time.
    

Problem conclusion

  • IBM Integration Bus no longer issues warnings to the integration
    server stderr file.
    It can be reverted to previous behaviour of issuing the warnings
    if the environment variable   MQSI_ENABLE_XLTXE_WARNINGS is set
    to any value.
    
    ---------------------------------------------------------------
    The fix is targeted for delivery in the following PTFs:
    
    Version    Maintenance Level
    v10.0      10.0.0.10
    v9.0       9.0.0.9
    
    The latest available maintenance can be obtained from:
    http://www-01.ibm.com/support/docview.wss?rs=849&uid=swg27006041
    
    If the maintenance level is not yet available,information on
    its planned availability can be found on:
    http://www-1.ibm.com/support/docview.wss?rs=849&uid=swg27006308
    ---------------------------------------------------------------
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT20854

  • Reported component name

    INTEGRATION BUS

  • Reported component ID

    5724J0530

  • Reported release

    900

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2017-06-02

  • Closed date

    2017-08-31

  • Last modified date

    2017-08-31

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    INTEGRATION BUS

  • Fixed component ID

    5724J0530

Applicable component levels

  • R900 PSY

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSNQK6","label":"IBM Integration Bus"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"9.0","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
23 March 2020