IBM Support

IT20587: THE AUTOMATED PROBE SCHEDULER IN SPECTRUM CONTROL DOESN'T WORK PROPERLY FOR MACHINES WITH NON-US LOCALE.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • The automated probe schedule is set in IBM Spectrum Control
    Web-GUI:
    click Settings > Automated Probe Schedule.
    
    The probes may not start at the specified time range when the
    IBM Spectrum Control server is installed on a machine where the
    LOCALE is non-US.
    The Schedule Balancer determines the first and last day of the
    balance week based on the Locale in use on that machine (in US,
    the "official" week is considered Sunday - Saturday, while in
    most European countries, the "official" week is considered
    Monday - Sunday).
    On the other hand, the Schedule Balancer is scheduled to run
    weekly, at midnight (in the time zone of the server) in the
    Saturday-Sunday night. This is OK for the server machines with
    Locale for which the week is considered Sunday - Saturday (like
    in US), but is not working properly for the server machines with
    Locale for which the week is considered Monday - Sunday (like in
    most European countries), for which the balancer should be
    scheduled to run weekly, at midnight (in the time zone of the
    server) in the Sunday-Monday night.
    
    Affected version:  Spectrum Control 5.2.13 and earlier.
    

Local fix

  • Please contact IBM support.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * IBM Spectrum Control 5.2.x users with Spectrum Control       *
    * installed on non-US locale server                            *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * The automated probe schedule set in IBM Spectrum Control may *
    * not start at the specified time range when the IBM Spectrum  *
    * Control server is installed on a machine where the locale is *
    * non-US.                                                      *
    *                                                              *
    * The Schedule Balancer in IBM Spectrum Control determines the *
    * first and last day of the balance week based on the Locale   *
    * in use on that machine (in US, the "official" week is        *
    * considered Sunday - Saturday, while in most European         *
    * countries, the "official" week is considered Monday -        *
    * Sunday).                                                     *
    *                                                              *
    * In addition, the Schedule Balancer is scheduled to run       *
    * weekly, at midnight (in the time zone of the server) the     *
    * night of Saturday-Sunday. This is OK for the server machines *
    * with Locale for which the week is considered Sunday -        *
    * Saturday (like in US), but is not working properly for the   *
    * server machines with Locale for which the week is considered *
    * Monday - Sunday (like in most European countries), for which *
    * the Balancer should be scheduled to run weekly, at midnight  *
    * (in the time zone of the server) in the Sunday-Monday night. *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * Apply fix maintenance when available                         *
    ****************************************************************
    

Problem conclusion

  • The fix for this APAR is targeted for the following maintenance
    package:
    
    | refresh pack | 5.2-TIV-TPC-RP0015 - target August 2017
    
    Fixed in IBM Spectrum Control 5.2.15
    
    http://www.ibm.com/support/docview.wss?&uid=swg21320822
    
    The target dates for future refresh packs do not represent a
    formal commitment by IBM. The dates are subject to change
    without notice.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT20587

  • Reported component name

    TPC ADVANCED

  • Reported component ID

    5608TPCA0

  • Reported release

    52D

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2017-05-15

  • Closed date

    2017-07-25

  • Last modified date

    2017-07-25

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TPC ADVANCED

  • Fixed component ID

    5608TPCA0

Applicable component levels

[{"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSNECY","label":"Tivoli Storage Productivity Center Advanced"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"52D"}]

Document Information

Modified date:
24 June 2022