Error description

  • Error Description:
    
    Snapdiff backup can fail with: ANS2836E. /vol/snapdiff/test is a
    partial volume or qtree
    when incorrect export path specification is used for  volume
    being backed up
    
    The message "ANS2836E  /vol/snapdiff/test is a partial volume or
    qtree"
    does not provide enough information to explain what is wrong
    with the export
    path specification and how to fix it.
    
    Here is an example that can cause the backup to fail:
    
     /vol/snapdiff/test
    
    Here is an example with correct volume name so backup can
    complete:
    
    /volume_snapdiff_test/
    
    Documentation needs to be updated to explain limitation
    regarding the export
    path used for the volume being backed up during  snapdiff
    backup.
    
    Tivoli Storage Manager Versions Affected:   71L
    
    
    Customer/L2 Diagnostics (If Applicable)
    
    When the backup fails, you may see the following in the client
    errorlog:
    
     ANS2836E Incremental backup operation using snapshot
    difference is only
     available for full volumes /vol/snapdiff/test is a partial
    volume or qtree.
    
    You will see the following in client service trace
    
    backsnap.cpp  (1644): BacHandleSnapshotPreProcess(): Found
    remote Volume<volume1>
    on NAS Filer: <YourNas.domain.name> for path  /vol/snapdiff/tes
    snapcommon.cpp (1178): scIsNasQtree(): NAS export path: <
    /volume1/snapdiff/test1> is a Qtree
    

Local fix

  • here is a new testflag called SNAPDIFFCMODEVOLPREFIX that
    will allow snapdiff backup to complete. This tesflag
    will work in 7 or C filer mode.
    
    The flag is specified in the client options file
    (dsm.opt) as follows:
    .
    TESTFLAGS SNAPDIFFCMODEVOLPREFIX
    

Problem summary

  • ****************************************************************
    

Problem conclusion

  • In IBM Tivoli Storage Manager for UNIX and Linux ClientsInstalla
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT20379

  • Reported component name

    TSM CLIENT

  • Reported component ID

    5698ISMCL

  • Reported release

    71L

  • Status

    CLOSED DOC

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2017-05-03

  • Closed date

    2017-07-28

  • Last modified date

    2017-07-28

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGSG7","label":"Tivoli Storage Manager"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"71L","Line of Business":{"code":"LOB26","label":"Storage"}}]

Document Information

Modified date:
07 January 2022