IBM Support

IT20211: IBM SPECTRUM CONTROL SERVICE TOOL DOES NOT COLLECT WEBSPHERE JAVACORE/HEAPDUMP FILES

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When logs are requested from a customer, they run service.bat
    (Windows servers) and service.sh (Unix servers).
    In 5.2.13, the service tool fails to collect the javacore and
    heap dump files from the WebSphere directories:
    <TPC_install_dir>\wlp\usr\servers\deviceServer
    <TPC_install_dir>\wlp\usr\servers\alertServer
    
    
    RECREATE STEPS:
    Run service.bat/service.sh, collect the resulting
    SCServiceFiles*.zip and notice no core or dump files collected.
    ________________________________________________________________
    DB2 Version used for Server:  		N/A
    The defect is against component:  	5608TPC00
    Server/Manager build/release (TPC):  	5.2.13
    
    ________________________________________________________________
    Problem as described by customer:  	support/development doesn't
    have needed core/dump files
    Initial customer impact (low/med/high): low
    

Local fix

  • Ask customers to manually collect javacore/heapdump files from
    the mentioned directories.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * IBM Spectrum Control 5.2.x users running the Service tool to *
    * collect diagnostics                                          *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * When Spectrum Control service logs are requested from a      *
    * customer, they run service.bat (Windows servers) and         *
    * service.sh (Unix servers).  In Spectrum Control 5.2.13, the  *
    * service tool fails to collect the javacore and               *
    * heap dump files from the WebSphere directories:              *
    * <TPC_install_dir>\wlp\usr\servers\deviceServer               *
    * <TPC_install_dir>\wlp\usr\servers\alertServer                *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * Apply fix maintenance when available                         *
    ****************************************************************
    

Problem conclusion

  • The fix for this APAR is targeted for the following maintenance
    package:
    
    | refresh pack | 5.2-TIV-TPC-RP0015 - target August 2017
    
    Fixed in IBM Spectrum Control 5.2.15
    
    http://www.ibm.com/support/docview.wss?&uid=swg21320822
    
    The target dates for future refresh packs do not represent a
    formal commitment by IBM. The dates are subject to change
    without notice.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT20211

  • Reported component name

    TPC

  • Reported component ID

    5608TPC00

  • Reported release

    52D

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2017-04-13

  • Closed date

    2017-07-07

  • Last modified date

    2017-07-07

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TPC

  • Fixed component ID

    5608TPC00

Applicable component levels

[{"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSNE44","label":"Tivoli Storage Productivity Center"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"52D"}]

Document Information

Modified date: