A fix is available
APAR status
Closed as program error.
Error description
There is a documented issue with VMware ESX 6.0: SCSI operations fail with out of memory messages (2146529) https://kb.vmware.com/kb/2146529 We need to update to a version that contains the fix. This issue is resolved in ESXi 6.0 Patch ESXi-6.0.0-20161104001.
Local fix
The customer can restart the compute node that is nearing heap exhaustion by executing the following steps: 1. Quiesce the compute node 2. Maintain the compute node 3. Check that all VMs have been moved off of the compute node before proceeding. If they have not, you can power off and store remaining workloads. If this is not an option, support can investigate why the VMs could not be migrated and can assess whether any workaround is available 4. Power off the node 5. Power on the node 6. Start the node
Problem summary
We have upgraded to VMware ESXi 6.0 patch 4 build 4600944.
Problem conclusion
A code fix is being provided in PureApplication System and BlueMix Local System version 2.2.3.0.
Temporary fix
Comments
APAR Information
APAR number
IT19336
Reported component name
PAPP SYS 8382 I
Reported component ID
5725G3200
Reported release
222
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-02-27
Closed date
2017-03-24
Last modified date
2017-03-24
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
PAPP SYS 8382 I
Fixed component ID
5725G3200
Applicable component levels
R223 PSY
UP
[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU053","label":"Cloud \u0026 Data Platform"},"Product":{"code":"SSM8NY","label":"PureApplication System"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.2.2.0"}]
Document Information
Modified date: