IBM Support

IT17608: IMPROPER SHUTDOWN OF IBM SPECTRUM CONTROL CAN RESULT IN DUPLICATE IDS BEING CREATED IN THE DATABASE

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • In cases where the IBM Spectrum Control device server process
    does not shut down cleanly, duplicate IDs can be created in the
    database resulting in failures to run jobs (probes, performance
    monitors, etc).
    The following example shows a probe job that fails to start
    (from the failing probe's job log):
    2016-MM-DD HH:MM:SS.xxx HWN021709I Collection for storage system
    Storwize <storage_device_name> completed.
    2016-MM-DD HH:MM:SS.xxx BTADS0102E The discover process that has
    the Device server run ID 393038 and job ID 870076 completed with
    one or more errors. The process status is 4 and the return code
    is 8 .
    The device server trace log shows the following being logged
    behind the above generic failure message:
    2016-MM-DD HH:MM:SS.xxx-xxxx Subsystem = <storage_device_wwpn>
    com.ibm.tpc.monitor.NAPIEventQueue notifyProbeFinished()
    NAPIPostProcess-10.123.48.187_<storage_device_name>
    2016-MM-DD HH:MM:SS.xxx-xxxx Batching is on.
    com.ibm.saas.agent.Dispatch run Dispatch
    2016-MM-DD HH:MM:SS.xxx-xxxx
    com.ibm.db2.jcc.am.SqlIntegrityConstraintViolationException: DB2
    SQL
    Error: SQLCODE=-803, SQLSTATE=23505,
    SQLERRMC=1;TPC.T_RES_SNAPSHOT_METADATA, DRIVER=3.65.77
    The referenced SQLCODE=-803 and SQLSTATE=23505 messages indicate
    a column unique value constraint violation in the database and
    this is caused by invalid/duplicate ID values that IBM Spectrum
    Control is trying to use.
    RECREATE STEPS:
    Device Server gets shut down but the shut down does not complete
    cleanly/as expected
    ________________________________________________________________
    DB2 Version used for Server:    N/A (any supported DB2 version)
    The defect is against component:   5608TPC00 (device server
    process)
    Server/Manager build/release (TPC):   5.2.11
    
    ________________________________________________________________
    Problem as described by customer:   scheduled and manual probes
    fail to run
    Initial customer impact (low/med/high): med
    Apply fixing level when available; contact support
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * IBM Spectrum Control 5.2.x users.                            *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * In cases where the IBM Spectrum Control device server        *
    * process does not shut down cleanly, duplicate IDs can be     *
    * created in the database resulting in failures to run jobs    *
    * (probes, performance monitors, etc).                         *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * Apply fix maintenance when available                         *
    ****************************************************************
    

Problem conclusion

  • The fix for this APAR is targeted for the following maintenance
    package:
    
    | refresh pack | 5.2-TIV-TPC-RP0014 - target May 2017
    
    Fixed in IBM Spectrum Control 5.2.14
    
    http://www.ibm.com/support/docview.wss?&uid=swg21320822
    
    The target dates for future refresh packs do not represent a
    formal commitment by IBM. The dates are subject to change
    without notice.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT17608

  • Reported component name

    TPC

  • Reported component ID

    5608TPC00

  • Reported release

    52B

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2016-10-21

  • Closed date

    2017-01-26

  • Last modified date

    2017-02-24

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TPC

  • Fixed component ID

    5608TPC00

Applicable component levels

[{"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSNE44","label":"Tivoli Storage Productivity Center"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"52B"}]

Document Information

Modified date:
24 June 2022