Fixes are available
APAR status
Closed as program error.
Error description
This issue occurs while the SVC event triggered miniprobe, thus preventing datapath information to be persisted. The following stack trace can be observed within the device server log : 2016-09-06 02:51:20.472+0200 Encountered an error trying to persist datapath information. java.lang.ClassCastException: java.lang.Integer incompatible with java.lang.String at com.ibm.tpc.infrastructure.mapping.CLISVC_DatapathToDBMapper.get SVID(CLISVC_DatapathToDBMapper.java:469) at com.ibm.tpc.infrastructure.mapping.CLISVC_DatapathToDBMapper.per sist(CLISVC_DatapathToDBMapper.java:282) at com.ibm.tpc.disk.collection.DiskCIMProcessor.persist(DiskCIMProc essor.java:2072) at com.ibm.tpc.discovery.parser.NAPI_DS_SVC_Parser.persistEntity(NA PI_DS_SVC_Parser.java:317) at com.ibm.tpc.discovery.parser.NAPI_DS_SVC_Parser.processOutputFil e(NAPI_DS_SVC_Parser.java:227) at com.ibm.tpc.discovery.parser.NAPI_DS_SVC_Parser.processOutputFil e(NAPI_DS_SVC_Parser.java:305) at com.ibm.tpc.monitor.NAPISVCEventMiniprobePostProcessor.parse(NAP ISVCEventMiniprobePostProcessor.java:212) at com.ibm.tpc.monitor.NAPISVCEventMiniprobePostProcessor.process(N APISVCEventMiniprobePostProcessor.java:164) at com.ibm.tpc.monitor.NAPIEventPostProcessThread.run(NAPIEventPost ProcessThread.java:189) com.ibm.tpc.infrastructure.mapping.CLISVC_DatapathToDBMapper persist(DBConnection pConn, Hashtable pParams, String pScanID) NAPIEventPostProcessThread_11.131.169.142_20160906-024517
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * IBM Spectrum Control 5.2.x users * **************************************************************** * PROBLEM DESCRIPTION: * * See ERROR DESCRIPTION. * **************************************************************** * RECOMMENDATION: * * Apply fix maintenance when available. * ****************************************************************
Problem conclusion
The fix for this APAR is targeted for the following maintenance package: | refresh pack | 5.2-TIV-TPC-RP0012 - target November 2016 Fixed in IBM Spectrum Control 5.2.12. http://www.ibm.com/support/docview.wss?&uid=swg21320822 The target dates for future refresh packs do not represent a formal commitment by IBM. The dates are subject to change without notice.
Temporary fix
Comments
APAR Information
APAR number
IT17161
Reported component name
TPC
Reported component ID
5608TPC00
Reported release
52B
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-09-22
Closed date
2016-09-26
Last modified date
2016-09-26
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
DISK
Fix information
Fixed component name
TPC
Fixed component ID
5608TPC00
Applicable component levels
R528 PSY
UP
R529 PSY
UP
R52A PSY
UP
R52B PSY
UP
[{"Line of Business":{"code":"LOB26","label":"Storage"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS5R93","label":"IBM Spectrum Control"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"52B"}]
Document Information
Modified date: