APAR status
Closed as program error.
Error description
When you want to use archecker to unload more than one compressed table with a single command file you may encounter error -569 "Cannot reference an external database with logging.". This will occur when the target database is not logged. It happens because usually the sysutils database is logged and the sysutils database is used by archecker to store the compression dictionaries read from the archive. To read the compression dictionary for the second (and following) tables a cross database query (from the target database to the sysutils database) is done that leads to error -569 when the logging mode is not matching. This explanation also opens the possibility of a work around. You can change the logging mode of the target database to match with sysutils.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * users of archecker table level restore who are restoring * * more than one compressed table in a non-logged database * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Update to IBM Informix Server 12.10.xC8 * ****************************************************************
Problem conclusion
Problem Fixed In IBM Informix Server 12.10.xC8
Temporary fix
Comments
APAR Information
APAR number
IT16965
Reported component name
INFORMIX SERVER
Reported component ID
5725A3900
Reported release
C10
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-09-08
Closed date
2016-12-09
Last modified date
2016-12-09
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
INFORMIX SERVER
Fixed component ID
5725A3900
Applicable component levels
RC10 PSY
UP