Fixes are available
APAR status
Closed as program error.
Error description
When installing VE 7.1.6.2 VMware GUI RPM on SLES 11, the following message will be seen: Data Protection for VMware GUI RPM registration failed. The following error will be encountered when registering the Data Protection for VMware GUI RPM on SLES 11 distributions. dependencies: rpmlib(FileDigests)<=4.6.0-1 is needed by TIVsm-TDPVMwarePlugin-7.1.6-2.x86_64) This problem will only occur when installing on SLES 11 distributions.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * Tivoli Storage Manager for Virtual Environments component * * Data Protection for VMware GUI version 7.1.6.2 running on * * SLES11 * **************************************************************** * PROBLEM DESCRIPTION: * * See ERROR DESCRIPTION * **************************************************************** * RECOMMENDATION: * * Apply fixing level when available. This problem is currently * * projected to be fixed in 7.1.6.3 . Note that the information * * is subject to change at the discretion of IBM. * ****************************************************************
Problem conclusion
The rpm TIVsm-TDPVMwarePlugin-7.1.6-2.x86_64 can not be installed onto a system with lower rpm level. This is now resolved.
Temporary fix
Comments
APAR Information
APAR number
IT16736
Reported component name
TSM FOR VE DP V
Reported component ID
5725TVEVM
Reported release
71L
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-08-24
Closed date
2016-09-06
Last modified date
2016-09-06
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
install
Fix information
Fixed component name
TSM FOR VE DP V
Fixed component ID
5725TVEVM
Applicable component levels
R71L PSY
UP
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS8TDQ","label":"Tivoli Storage Manager for Virtual Environments"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"71L","Line of Business":{"code":"LOB26","label":"Storage"}}]
Document Information
Modified date: