IBM Support

IT15716: V7K STORAGE DEVICE PROBE FAILS WITH HWNEP0002E ALONG WITH STATUS= 4 , RETURN CODE= 8.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • The probes fails due to a property called "expirationtimeout"
    is assigned with a 'not-applicable' value instead 'disabled' or
    'int' value.
    
    Probe Results:
    
    2016-06-14 05:30:19.360-0700 HWNEP0002E Log/output file,
    <device>_output.txt, not found or failed to load.
    2016-06-14 05:30:19.766-0700 HWN021709I Collection for storage
    system <device> completed.
    2016-06-14 05:30:19.954-0700 BTADS0001I Discover Process with
    Device Server RUN ID <value> and Job ID <value> is complete with
    Status= 4 , Return Code= 8.
    
    In dmSVCTrace.log the following error appear :
    
    java.lang.NumberFormatException: For input string:
    "not-applicable"
    
    RECREATE STEPS:
    Run probe to target v7k storage device and view results.
    
    ________________________________________________________________
    
    DB2 Version used for Server: N/A
    The defect is against component: 5608TPCA0
    Server/Manager build/release (TPC): 5.2.9
    Agent build/release (TPC): N/A
    Server/Manager (OS):  WIN2012-R2
    Agent (OS):   N/A
    ________________________________________________________________
    
    Problem as described by customer:  Unable to Probe v7k.
    Initial customer impact (low/med/high):  med
    

Local fix

  • Contact Support
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * IBM Spectrum Control 5.2.x users monitoring Storwize V7000   *
    * storage systems                                              *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * Probe failes with HWNEP0002E.  See ERROR DESCRIPTION.        *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * Apply fix maintenance when available.                        *
    ****************************************************************
    

Problem conclusion

  • The fix for this APAR is targeted for the following maintenance
    package:
    
    | refresh pack | 5.2-TIV-TPC-RP0012 - target November 2016
    
    Fixed in IBM Spectrum Control 5.2.12.
    
    http://www.ibm.com/support/docview.wss?&uid=swg21320822
    
    The target dates for future refresh packs do not represent a
    formal commitment by IBM. The dates are subject to change
    without notice.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT15716

  • Reported component name

    TPC ADVANCED

  • Reported component ID

    5608TPCA0

  • Reported release

    529

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2016-06-21

  • Closed date

    2016-09-26

  • Last modified date

    2016-09-26

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • DISK
    

Fix information

  • Fixed component name

    TPC ADVANCED

  • Fixed component ID

    5608TPCA0

Applicable component levels

  • R529 PSY

       UP

  • R52A PSY

       UP

  • R52B PSY

       UP

  • R528 PSY

       UP

[{"Line of Business":{"code":"LOB26","label":"Storage"},"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSNECY","label":"Tivoli Storage Productivity Center Advanced"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"529"}]

Document Information

Modified date:
25 September 2021