IBM Support

IT14473: INITIAL PATH PANEL NOT SHOWING CORRECT STATUS

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as Permanent restriction.

Error description

  • Path summary panel shows stale number of failing paths for some
    DS8K boxes when the panel was first invoked (due to refresh from
     cache/Derby), but seconds later changed to correct status when
    a refresh from hardware occurs:
    > 2016-03-29 08:29:04.248+0200 CSMCOM-1884 RepMgr D >
    com.ibm.csm.server.hw.ess.ccw.ESSPathStateProcessor
    checkPathStatus(boolean,ESSPathIdentification) Entry
    
    When user brings up the Path panel, it should display the
    correct path status or showing a timestamp indicating the status
    might be stale. This leads to these potential APAR changes:
    - Put into the TPC-R doc that data first displayed might be
    stale and user has to wait xx seconds for the display to refresh
    (not a good option)
    - Put a second timestamp showing the last time the path status
    was refreshed from hardware (better option)
    - Do not display path status until hardware refresh is
    completed, so there is no stale information shown (best option)
    

Local fix

  • Wait for xx seconds for the hardware refresh to occur, then it
    would show the correct path status.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * TPC-R 5.2.x users                                            *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * See ERROR DESCRIPTION.                                       *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • There is no change for this APAR as it work as designed.  Th
    TPC-R 5.2.8 Path summary panel shows stale number of failing
    paths for some DS8K boxes when the panel was first invoked, but
    seconds later changed to correct status. First time we display
    this status we display it according to our database and then
    query the subsystem for status. The second time, after a GUI
    refresh we display the correct data.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT14473

  • Reported component name

    TPC

  • Reported component ID

    5608TPC00

  • Reported release

    528

  • Status

    CLOSED PRS

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2016-04-06

  • Closed date

    2016-08-05

  • Last modified date

    2016-08-05

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    IT16319

Modules/Macros

  • TPCR
    

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS5R93","label":"IBM Spectrum Control"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"528","Edition":"","Line of Business":{"code":"LOB26","label":"Storage"}}]

Document Information

Modified date:
22 February 2022