Direct links to fixes
4.7.0.4-SterlingConnectDirectforMicrosoftWindows-x86-fp0004-if007
4.6.0.6-SterlingConnectDirectforMicrosoftWindows-x86-fp0006-if008
4.7.0.4-SterlingConnectDirectforMicrosoftWindows-x86-fp0004-if016
4.6.0.6-SterlingConnectDirectforMicrosoftWindows-x86-fp0006-if009
4.6.0.6-SterlingConnectDirectforMicrosoftWindows-x86-fp0006
4.6.0.6-SterlingConnectDirectforMicrosoftWindows-x86-fp0006-if013
4.6.0.6-SterlingConnectDirectforMicrosoftWindows-x86-fp0006-if015
4.7.0.5-SterlingConnectDirectforMicrosoftWindows-x86-fp0005
4.6.0.6-SterlingConnectDirectforMicrosoftWindows-x86-fp0006-if018
4.7.0.4-SterlingConnectDirectforMicrosoftWindows-x86-fp0004-if023
4.7.0.5-SterlingConnectDirectforMicrosoftWindows-x86-fp0005-if006
4.7.0.5-SterlingConnectDirectforMicrosoftWindows-x86-fp0005-if013
4.7.0.5-SterlingConnectDirectforMicrosoftWindows-x86-fp0005-if016
4.7.0.5-SterlingConnectDirectforMicrosoftWindows-x86-fp0005-if025
4.7.0.6-SterlingConnectDirectforMicrosoftWindows-x86-fp0006
4.7.0.6-SterlingConnectDirectforMicrosoftWindows-x86-fp0006-if005
4.7.0.6-SterlingConnectDirectforMicrosoftWindows-x86-fp0006-if006
4.7.0.6-SterlingConnectDirectforMicrosoftWindows-x86-fp0006-if012
4.7.0.7-SterlingConnectDirectforMicrosoftWindows-x86-fp0007
4.7.0.7-SterlingConnectDirectforMicrosoftWindows-x86-fp0007-if001
4.7.0.7-SterlingConnectDirectforMicrosoftWindows-x86-fp0007-if009
4.7.0.7-SterlingConnectDirectforMicrosoftWindows-x86-fp0007-if016
4.7.0.7-SterlingConnectDirectforMicrosoftWindows-x86-fp0007-if018
4.7.0.7-SterlingConnectDirectforMicrosoftWindows-x86-fp0007-if021
4.7.0.7-SterlingConnectDirectforMicrosoftWindows-x86-fp0007-if023
Sterling Connect:Direct for Microsoft Windows 4.6.0 Fix Packs
APAR status
Closed as program error.
Error description
Connect:Direct Windows process trying to do a remote RUN TASK on UNIX. The command line includes a pipe char, like: RUN TASK (PGM=UNIX) SNODE (SYSOPTS="cd /usr/local/data \; /bin/cp -f ´/bin/ls | head -1´ /tmp \;") This command, when it reaches the UNIX server, doubles the pipe (|), making it ||, which stands for OR in UNIX. So, the command succeeds, but copies all files instead of just one file.
Local fix
STRRTC - 480005 VF / VF Circumvention: None
Problem summary
Users Affected: Sterling Connect:Direct for Windows 4.5.00 Sterling Connect:Direct for Windows 4.5.01 Sterling Connect:Direct for Windows 4.6.0 Sterling Connect:Direct for Windows 4.7.0 Problem Description: Pipe characters are doubled (||) in a RUN TASK/JOB step on a Sterling Connect:Direct UNIX SNODE. This affects the way that the UNIX shell interprets the specified command line, because "|" and "||" have a different meaning. Platforms Affected: Windows
Problem conclusion
Resolution Summary: Fixed. Also resolved a memory leak when FMH71 format conversion has failed (LSMG613I). Delivered In: Sterling Connect:Direct for Windows 4.6.0.5_iFix029 Sterling Connect:Direct for Windows 4.7.0.4_iFix002
Temporary fix
Comments
APAR Information
APAR number
IT13962
Reported component name
STR CD FOR WIND
Reported component ID
5725C9908
Reported release
470
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-02-24
Closed date
2016-05-10
Last modified date
2016-05-10
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
STR CD FOR WIND
Fixed component ID
5725C9908
Applicable component levels
Document Information
Modified date:
28 August 2023