Direct links to fixes
4.7.0.4-SterlingConnectDirectforMicrosoftWindows-x86-fp0004
4.6.0.5-SterlingConnectDirectforMicrosoftWindows-x86-fp0005-if028
4.7.0.4-SterlingConnectDirectSDK-x86-fp0004
4.7.0.4-SterlingConnectDirectRequesterStandAlone-x86-fp0004
4.6.0.5-SterlingConnectDirectSDK-x86-fp0005-if028
4.6.0.5-SterlingConnectDirectRequesterStandAlone-x86-fp0005-if028
4.6.0.6-SterlingConnectDirectforMicrosoftWindows-x86-fp0006
4.7.0.4-SterlingConnectDirectforMicrosoftWindows-x86-fp0004-if007
4.6.0.6-SterlingConnectDirectforMicrosoftWindows-x86-fp0006-if008
4.7.0.4-SterlingConnectDirectforMicrosoftWindows-x86-fp0004-if016
4.6.0.6-SterlingConnectDirectforMicrosoftWindows-x86-fp0006-if009
4.6.0.6-SterlingConnectDirectforMicrosoftWindows-x86-fp0006-if013
4.6.0.6-SterlingConnectDirectforMicrosoftWindows-x86-fp0006-if015
4.7.0.5-SterlingConnectDirectforMicrosoftWindows-x86-fp0005
4.7.0.5-SterlingConnectDirectSDK-x86-fp0005
4.7.0.5-SterlingConnectDirectRequesterStandAlone-x86-fp0005
4.6.0.6-SterlingConnectDirectforMicrosoftWindows-x86-fp0006-if018
4.6.0.6-SterlingConnectDirectRequesterStandAlone-x86-fp0006-if018
4.6.0.6-SterlingConnectDirectSDK-x86-fp0006-if018
4.7.0.4-SterlingConnectDirectforMicrosoftWindows-x86-fp0004-if023
4.7.0.5-SterlingConnectDirectforMicrosoftWindows-x86-fp0005-if006
4.7.0.5-SterlingConnectDirectforMicrosoftWindows-x86-fp0005-if013
4.7.0.5-SterlingConnectDirectforMicrosoftWindows-x86-fp0005-if016
4.7.0.5-SterlingConnectDirectRequesterStandAlone-x86-fp0005-if016
4.7.0.5-SterlingConnectDirectSDK-x86-fp0005-if016
4.7.0.5-SterlingConnectDirectRequesterStandAlone-x86-fp0005-if025
4.7.0.5-SterlingConnectDirectSDK-x86-fp0005-if025
4.7.0.5-SterlingConnectDirectforMicrosoftWindows-x86-fp0005-if025
4.7.0.6-SterlingConnectDirectforMicrosoftWindows-x86-fp0006
4.7.0.6-SterlingConnectDirectRequesterStandAlone-x86-fp0006
4.7.0.6-SterlingConnectDirectSDK-x86-fp0006
4.7.0.6-SterlingConnectDirectforMicrosoftWindows-x86-fp0006-if005
4.7.0.6-SterlingConnectDirectRequesterStandAlone-x86-fp0006-if005
4.7.0.6-SterlingConnectDirectSDK-x86-fp0006-if005
4.7.0.6-SterlingConnectDirectforMicrosoftWindows-x86-fp0006-if006
4.7.0.6-SterlingConnectDirectforMicrosoftWindows-x86-fp0006-if012
4.7.0.7-SterlingConnectDirectforMicrosoftWindows-x86-fp0007
4.7.0.7-SterlingConnectDirectSDK-x86-fp0007
4.7.0.7-SterlingConnectDirectRequesterStandAlone-x86-fp0007
4.7.0.7-SterlingConnectDirectforMicrosoftWindows-x86-fp0007-if001
4.7.0.7-SterlingConnectDirectforMicrosoftWindows-x86-fp0007-if009
4.7.0.7-SterlingConnectDirectRequesterStandAlone-x86-fp0007-if009
4.7.0.7-SterlingConnectDirectSDK-x86-fp0007-if009
4.7.0.7-SterlingConnectDirectforMicrosoftWindows-x86-fp0007-if016
4.7.0.7-SterlingConnectDirectforMicrosoftWindows-x86-fp0007-if018
4.7.0.7-SterlingConnectDirectforMicrosoftWindows-x86-fp0007-if021
4.7.0.7-SterlingConnectDirectforMicrosoftWindows-x86-fp0007-if023
Sterling Connect:Direct for Microsoft Windows 4.6.0 Fix Packs
APAR status
Closed as program error.
Error description
When using IBM solidDB and running a Select Statistics command filtering by a node or process name, the statistics do not come up for nodes or processes that are in lower- or mixed-case.
Local fix
STRRTC - 485087 VF / VF Circumvention: None
Problem summary
Users Affected: Sterling Connect:Direct for Windows 4.6.0 Sterling Connect:Direct for Windows 4.7.0 Problem Description: The Select Statistics command cannot filter for node or process names containing lower-case characters. Such names may come from a remote Sterling Connect:Direct UNIX node. This issue only applies when the database is solidDB and the command is issued by a Windows SDK client, including CD Requester and the CLI. It does not apply to clients using the Application Interface for Java (AIJ). Platforms Affected: Windows
Problem conclusion
Resolution Summary: Updated the SDK - and thus its clients - to preserve the case for node and process name specified on Select Statistics commands. Note that the parameters pname, pnode, snode and rmtnode are case-sensitive when the database is solidDB. Delivered In: Sterling Connect:Direct for Windows 4.6.0.5_iFix025 Sterling Connect:Direct for Windows 4.7.0.3_iFix024
Temporary fix
Comments
APAR Information
APAR number
IT13734
Reported component name
STR CD FOR WIND
Reported component ID
5725C9908
Reported release
470
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-02-11
Closed date
2016-03-10
Last modified date
2016-03-10
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
STR CD FOR WIND
Fixed component ID
5725C9908
Applicable component levels
Document Information
Modified date:
28 August 2023