IBM Support

IT13608: PUREAPPLICATION SYSTEM IBM OS IMAGE FOR AIX SYSTEMS V2.1.3.0 DETECTING THE SIT0 INTERFACE AS PUBLIC INTERFACE VARIABLE

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Customer is reporting that after installing IBM OS AIX Image
    version 2.1.3.0, that the version 2.1.3.0 image has the sit0
    interface configured as a valid IPv4 address, however; it should
    be an IPv6 address.
    
    Example:
    OS AIX Image 2.1.3.0:
    # ifconfig -a
    en0:
    flags=1e084863,480<UP,BROADCAST,NOTRAILERS,RUNNING,SIMPLEX,MULTI
    CAST,GRO
    UPRT,64BIT,CHECKSUM_OFFLOAD(ACTIVE),CHAIN>
            inet6 xxxx:xxxx:xxxx:xx:xxxx:xxxx:xxxx:xxxx/xx
            inet6 xxxx::xxxx:xxxx:xxxx:xxxx/xx
             tcp_sendspace 262144 tcp_recvspace 262144 rfc1323 1
    en1:
    flags=1e084863,4c0<UP,BROADCAST,NOTRAILERS,RUNNING,SIMPLEX,MULTI
    CAST,GRO
    UPRT,64BIT,CHECKSUM_OFFLOAD(ACTIVE),LARGESEND,CHAIN>
            inet xx.xxx.xx.xxxx netmask 0xffffff00 broadcast
    xx.xxx.xxx.xxx
             tcp_sendspace 262144 tcp_recvspace 262144 rfc1323 1
    sit0: flags=8100041<UP,RUNNING,LINK0>
            inet6 ::xx.xxx.xx.xxx/xx
    lo0:
    flags=e08084b,c0<UP,BROADCAST,LOOPBACK,RUNNING,SIMPLEX,MULTICAST
    ,GROUPRT
    ,64BIT,LARGESEND,CHAIN>
            inet xxx.x.x.x netmask 0xff000000 broadcast
    xxx.xxx.xxx.xxx
            inet6 ::1%1/128
             tcp_sendspace 131072 tcp_recvspace 131072 rfc1323 1
    The customer reported this problem after attempting to install
    IBM Patterns and from the standard.out file the customer was
    able to see the interface was not getting configured properly
    and was choosing the public_interface variable value sit0. The
    pattern detects the sit0 interface as public interface,
    however; it should find the en1 interface.
    ######################################
    Getting public interface name
    ######################################
    Public interface name: sit0
    ######################################
    Getting gateway ip for use as quorum device
    ######################################
    Gateway IP:
    Validating ip address ->
    Error: Empty IP address!
    

Local fix

  • Customers can try the following to see if autoconf6 -6 will
    skip creating tunnel interface
    in the customer environment.
    
    The original autoconf6 command without -6 does not create sit0
    interface in the IBM test environment.
    
    1. open /etc/rc.tcpip and comment out the following line
       start /usr/sbin/autoconf6 "" " -Ri en0 "
    
    2. reboot the VM
       shutdown -r now
    
    3. run the following command when VM is up
      /usr/sbin/autoconf6 -6 -Ri eth0
    
    4. run ifconfig -a to see if sit0 is present or not.
    
    If autoconf6 -6 does not create sit0 interface,  the customer
    can create a new image using the following:
    
    1. extend the image
    
    2. logon the extended instance,  then open
    /opt/IBM/AE/AS/vmc-net-interface/dmtf_network_bringup
       search "acopt=",  it should return 2 lines.
       replace acopt="-i"  with acopt="-6 -i"
       replace acopt="-Ri" with acopt="-6 -Ri"
    
    3. capture the image
    In the new deployment,  autoconf6 should have -6 option defined
    in rc.tcpip.
    

Problem summary

  • The sit0 interface was being configured in error.
    

Problem conclusion

  • A code fix is being provided in PureApplication System
    version 2.2.0.0 in the IBM OS Image for AIX Systems version
    2.1.5.0 and version 1.1.5.0.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT13608

  • Reported component name

    PAPP SYS 8278 P

  • Reported component ID

    5725F4600

  • Reported release

    211

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2016-02-03

  • Closed date

    2016-02-18

  • Last modified date

    2016-02-18

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    PAPP SYS 8278 P

  • Fixed component ID

    5725F4600

Applicable component levels

  • R220 PSY

       UP

[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU053","label":"Cloud \u0026 Data Platform"},"Product":{"code":"SSM8NY","label":"PureApplication System"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"211"}]

Document Information

Modified date:
26 September 2021