IBM Support

IT13462: CREATE NEW XLATE TABLES THAT WILL FUNCTION PROPERLY USING CODEPAGE 037 AS THE MVS SYSTEM

Direct links to fixes

4.7.0.4-SterlingConnectDirectforMicrosoftWindows-x86-fp0004
4.6.0.5-SterlingConnectDirectforMicrosoftWindows-x86-fp0005-if028
4.7.0.4-SterlingConnectDirectRequesterStandAlone-x86-fp0004
4.6.0.5-SterlingConnectDirectRequesterStandAlone-x86-fp0005-if028
4.6.0.6-SterlingConnectDirectforMicrosoftWindows-x86-fp0006
4.7.0.4-SterlingConnectDirectforMicrosoftWindows-x86-fp0004-if007
4.6.0.6-SterlingConnectDirectforMicrosoftWindows-x86-fp0006-if008
4.7.0.4-SterlingConnectDirectforMicrosoftWindows-x86-fp0004-if016
4.6.0.6-SterlingConnectDirectforMicrosoftWindows-x86-fp0006-if009
4.6.0.6-SterlingConnectDirectforMicrosoftWindows-x86-fp0006-if013
4.6.0.6-SterlingConnectDirectforMicrosoftWindows-x86-fp0006-if015
4.7.0.5-SterlingConnectDirectforMicrosoftWindows-x86-fp0005
4.7.0.5-SterlingConnectDirectRequesterStandAlone-x86-fp0005
4.6.0.6-SterlingConnectDirectforMicrosoftWindows-x86-fp0006-if018
4.6.0.6-SterlingConnectDirectRequesterStandAlone-x86-fp0006-if018
4.7.0.4-SterlingConnectDirectforMicrosoftWindows-x86-fp0004-if023
4.7.0.5-SterlingConnectDirectforMicrosoftWindows-x86-fp0005-if006
4.7.0.5-SterlingConnectDirectforMicrosoftWindows-x86-fp0005-if013
4.7.0.5-SterlingConnectDirectforMicrosoftWindows-x86-fp0005-if016
4.7.0.5-SterlingConnectDirectRequesterStandAlone-x86-fp0005-if016
4.7.0.5-SterlingConnectDirectRequesterStandAlone-x86-fp0005-if025
4.7.0.5-SterlingConnectDirectforMicrosoftWindows-x86-fp0005-if025
4.7.0.6-SterlingConnectDirectforMicrosoftWindows-x86-fp0006
4.7.0.6-SterlingConnectDirectRequesterStandAlone-x86-fp0006
4.7.0.6-SterlingConnectDirectforMicrosoftWindows-x86-fp0006-if005
4.7.0.6-SterlingConnectDirectRequesterStandAlone-x86-fp0006-if005
4.7.0.6-SterlingConnectDirectforMicrosoftWindows-x86-fp0006-if006
4.7.0.6-SterlingConnectDirectforMicrosoftWindows-x86-fp0006-if012
4.7.0.7-SterlingConnectDirectforMicrosoftWindows-x86-fp0007
4.7.0.7-SterlingConnectDirectRequesterStandAlone-x86-fp0007
4.7.0.7-SterlingConnectDirectforMicrosoftWindows-x86-fp0007-if001
4.7.0.7-SterlingConnectDirectforMicrosoftWindows-x86-fp0007-if009
4.7.0.7-SterlingConnectDirectRequesterStandAlone-x86-fp0007-if009
4.7.0.7-SterlingConnectDirectforMicrosoftWindows-x86-fp0007-if016
4.7.0.7-SterlingConnectDirectforMicrosoftWindows-x86-fp0007-if018
4.7.0.7-SterlingConnectDirectforMicrosoftWindows-x86-fp0007-if021
4.7.0.7-SterlingConnectDirectforMicrosoftWindows-x86-fp0007-if023
Sterling Connect:Direct for Microsoft Windows 4.6.0 Fix Packs

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as new function.

Error description

  • When copying text files to or from an EBCDIC remote node, C:D
    Windows translates ASCII data to EBCDIC and vice versa as
    needed. In some cases, an alternative to the default ASCII to
    EBCDIC translation provided by C:D Windows is desired.
    

Local fix

  • STRRTC - 489446
    VF / VF
    Circumvention: None
    

Problem summary

  • Users Affected:
    Sterling Connect:Direct for Windows 4.5.00
    Sterling Connect:Direct for Windows 4.5.01
    Sterling Connect:Direct for Windows 4.6.0
    Sterling Connect:Direct for Windows 4.7.0
    
    Problem Description:
    When copying text files to or from an EBCDIC remote node,
    Connect:Direct Windows translates ASCII data to EBCDIC and vice
    versa as needed. In some cases, an alternative to the default
    ASCII to EBCDIC translation provided by Connect:Direct Windows
    is desired.
    
    Platforms Affected:
    Windows
    

Problem conclusion

  • Resolution Summary:
    While the product includes options for users to create their
    own custom xlate tables or to use codepage translation, for
    convenience, new xlate tables are provided that convert
    ISO-8859-1 ASCII text to IBM-037 EBCDIC and back. These xlate
    tables, ISOtoIBM.cdx and IBMtoISO.cdx, are located in the
    Server\xlate subfolder. They may be specified in copy step
    sysopts, or be made the default translation by specifying them
    in the Global Copy Parameters section of the initialization
    parameters.
    
    Delivered In:
    Sterling Connect:Direct for Windows 4.6.0.5_iFix023
    Sterling Connect:Direct for Windows 4.7.0.3_iFix021
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT13462

  • Reported component name

    STR CD FOR WIND

  • Reported component ID

    5725C9908

  • Reported release

    460

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2016-01-28

  • Closed date

    2016-03-10

  • Last modified date

    2016-03-10

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    STR CD FOR WIND