A fix is available
APAR status
Closed as program error.
Error description
A user was performing a restore from backup on an IBM PureApplication System W3700. The restore failed with the following error message: BackupRestoreException: CWZIP9605E Configuration of PowerVC failed. backup.BackupHmcAndPowerVC.restore (BackupHmcAndPowerVC.groovy:136) ... job.queue | fail: job has no message defined -- building message from Throwable: com.ibm.iaas.backup.util.BackupRestoreException: CWZIP9605E Configuration of PowerVC failed. The failure occurred because the PowerVC could not contact the Hardware Management Console (HMC): PD-A000133 There is no route to the IP address or host name specified for the Hardware Management Console.", "code": 400
Local fix
Problem summary
A timing window during the reboot of a resource that occurs during the restore operation caused the PowerVC to HMC connection error.
Problem conclusion
A code fix is being provided in PureApplication System version 2.1.2.0.
Temporary fix
Comments
APAR Information
APAR number
IT12518
Reported component name
PAPP SYS 8278 P
Reported component ID
5725F4600
Reported release
211
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2015-12-01
Closed date
2015-12-01
Last modified date
2017-02-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
PAPP SYS 8278 P
Fixed component ID
5725F4600
Applicable component levels
R212 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSM8NY","label":"PureApplication System"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"211","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
02 February 2017