Fixes are available
APAR status
Closed as program error.
Error description
In some cases Online Certificate Status Protocol (OCSP) transactions, Web Service Registry and repository (WSRR) subscription renewals, or XC10 commands can stall when persistent connections are used to the server. The stall will last the duration of the configured timeout.
Local fix
Disable persistent connections on the server side.
Problem summary
Affected are DataPower configurations using OCSP or WSRR protocol or XC10 integration. When persistent connections are used to communicate with such backend system, the data transfer may stall, resulting in timeout and incomplete transfer.
Problem conclusion
The fix is available in 7.0.0.13, 7.1.0.10, 7.2.0.6 and 7.5.0.0 For a list of the latest fix packs available, please see: http://www-01.ibm.com/support/docview.wss?uid=swg21237631
Temporary fix
Comments
APAR Information
APAR number
IT12248
Reported component name
DATAPOWER
Reported component ID
DP1234567
Reported release
710
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2015-11-12
Closed date
2016-02-04
Last modified date
2016-05-21
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
DATAPOWER
Fixed component ID
DP1234567
Applicable component levels
R700 PSN
UP
R710 PSN
UP
R720 PSN
UP