A fix is available
APAR status
Closed as program error.
Error description
A problem with the ownership of the data collector home directory prevents the monitoring service from restarting the WebSphere Application Server after the data collector configuration step. The error in the logs is: itcamwas 1 pid=33751274 DEBUG [OUT] runConfigActions script execution failed. Exit code: 1 Exception caught while waiting for runConfigActions script to complete: /prod/wesadm/wes/was85/base/profiles/[proflle_name]/bin/ runConfigActions.sh
Local fix
Ø NA
Problem summary
The data collector directory ownership permissions were not allowing for required access
Problem conclusion
A code fix is being provided in PureApplication System version 2.1.2.0 in the System Monitoring Pattern version 1.0.6.0.
Temporary fix
Comments
APAR Information
APAR number
IT12197
Reported component name
PAPP SYS 8278 P
Reported component ID
5725F4600
Reported release
211
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2015-11-10
Closed date
2015-11-20
Last modified date
2015-11-20
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
PAPP SYS 8278 P
Fixed component ID
5725F4600
Applicable component levels
R212 PSY
UP
[{"Line of Business":{"code":"LOB10","label":"Data and AI"},"Business Unit":{"code":"BU053","label":"Cloud \u0026 Data Platform"},"Product":{"code":"SSM8NY","label":"PureApplication System"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"211"}]
Document Information
Modified date:
26 September 2021