A fix is available
APAR status
Closed as program error.
Error description
After upgrading the PureApplication System to version 2.1.0.2 the System Monitoring instance is stuck in maintenance mode.
Local fix
1. Download deployment.json from storehouse browser for the System Monitoring Instance, update the value of "update.canCommitOrRevert" from false to true, then save and upload the deployment.json back to the same location in the storehouse browser. Ensure when uploading that Content-Type is set to: application/json 2. Click "commit" again on the UI to finish the System Monitoring update process.
Problem summary
An unhandled exception that occurred while processing the deployment.json was preventing the successful completion of the monitoring environment upgrade.
Problem conclusion
A code fix is being provided in PureApplication System version 2.2.0.0.
Temporary fix
Comments
APAR Information
APAR number
IT12070
Reported component name
PAPP SYS 8382 I
Reported component ID
5725G3200
Reported release
210
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2015-11-02
Closed date
2016-02-16
Last modified date
2016-02-16
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
PAPP SYS 8382 I
Fixed component ID
5725G3200
Applicable component levels
R220 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSM8NY","label":"PureApplication System"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.1.0.0","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date: