Fixes are available
IBM Spectrum Control V5.2.10 (May 2016)
IBM Spectrum Control V5.2.10.1 (July 2016)
IBM Spectrum Control V5.2.11 (August 2016)
IBM Spectrum Control V5.2.12 (November 2016)
IBM Spectrum Control V5.2.13 (March 2017)
IBM Spectrum Control V5.2.14 (May 2017)
IBM Spectrum Control V5.2.15 (August 2017)
IBM Spectrum Control V5.2.15.2 (November 2017)
IBM Spectrum Control V5.2.16 (March 2018)
IBM Spectrum Control V5.2.17 (May 2018)
APAR status
Closed as program error.
Error description
In the TPC SRA probe logs the following messages are displayed: 2015-09-30 01:46:07.252 STA0196I Unsupported request reported by device /dev/hdisk0 2015-09-30 01:46:07.469 STA0523E Command execution failed. The error "STA0523E Command execution failed" occurs when AIX multipath driver is installed but no multipath device has been created.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * Users using SRA on AIX with SDD driver installed but no * * mulitpath devices configured. * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Apply fix maintenance when available. * ****************************************************************
Problem conclusion
Do not log the error "STA0523E Command execution failed." when pcmpath query device returns no device. The fix for this APAR is targeted for the following maintenance package: | refresh pack | 5.2-TIV-TPC-RP0010 - target 2Q16 Fixed in IBM Spectrum Control 5.2.10. http://www-01.ibm.com/support/docview.wss?&uid=swg21320822 The target dates for future refresh packs do not represent a formal commitment by IBM. The dates are subject to change without notice.
Temporary fix
Comments
APAR Information
APAR number
IT11922
Reported component name
TPC ADVANCED
Reported component ID
5608TPCA0
Reported release
526
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2015-10-22
Closed date
2016-01-20
Last modified date
2016-01-20
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
SRA
Fix information
Fixed component name
TPC ADVANCED
Fixed component ID
5608TPCA0
Applicable component levels
R526 PSY
UP
R527 PSY
UP
R528 PSY
UP
R520 PSY
UP
[{"Line of Business":{"code":"LOB26","label":"Storage"},"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSNECY","label":"Tivoli Storage Productivity Center Advanced"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"526"}]
Document Information
Modified date: