IBM Support

IT11730: SWITCHES WITH WWNS THAT CONTAIN THE OUI VALUE '8C604' FROM DEVICES ARE NOT RECOGNIZED BY TPC.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • New Cisco Device has added a new OUI value which is not
    recognized by TPC.
    Because of this information for these switches and their
    fabrics may not  be collected as expected  and may result in
    functional limitations and or data not being able to be viewed
    from the TPC-UI.
    
    
    RECREATE STEPS:  Add new Cisco device to TPC and view results
    after probe and performance monitor job runs.
    probe and performance monitor job runs.
    

Local fix

  • Contact Support.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * 5.2.x and 5.1.x                                              *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * New Cisco Device has added a new OUI value (8C604F) in the   *
    * WWN which is not recognized by TPC 5.2.7 and earlier and TPC *
    * 5.1.1.9 and earlier.                                         *
    *                                                              *
    * Data for these switches and their fabrics may not  be        *
    * collected as expected and may result in functional           *
    * limitations and or data not being available from the TPC-UI. *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * Apply fix maintenance when available.                        *
    * Alternatively, you can add the value to the TPC database to  *
    * address the issue until the next fix can be applied.  You    *
    * should have a backed up copy of your database before making  *
    * any changes.                                                 *
    *                                                              *
    * Log into server with db2admin or db2inst1 (or equivalent,    *
    * depending on platform)                                       *
    *                                                              *
    * connect to TPCDB                                             *
    * db2 set schema tpc                                           *
    * db2 "insert into T_RES_OUI values ('8C604F','Cisco')"        *
    * Initiate Fabric discovery in TPC or (VMcontrol Farm and      *
    * *                                                            *
    * Switch                                                       *
    * *                                                            *
    *  inventory)                                                  *
    ****************************************************************
    

Problem conclusion

  • Added the new OUI value to TPC.  The fix for this APAR is
    targeted for the following maintenance package:
    
    | refresh pack | 5.2-TIV-TPC-RP0008 - target December 2015
    | fix pack | 5.1.1-TIV-TPC-FP0010 - target TBD
    
    http://www-01.ibm.com/support/docview.wss?&uid=swg21320822
    
    The target dates for future refresh packs do not represent a
    formal commitment by IBM. The dates are subject to change
    without notice.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT11730

  • Reported component name

    TPC ADVANCED

  • Reported component ID

    5608TPCA0

  • Reported release

    510

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2015-10-14

  • Closed date

    2015-11-18

  • Last modified date

    2015-11-18

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • FABRIC
    

Fix information

  • Fixed component name

    TPC ADVANCED

  • Fixed component ID

    5608TPCA0

Applicable component levels

  • R510 PSY

       UP

  • R520 PSY

       UP

  • R527 PSY

       UP

[{"Line of Business":{"code":"LOB26","label":"Storage"},"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSNECY","label":"Tivoli Storage Productivity Center Advanced"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"510"}]