APAR status
Closed as program error.
Error description
A trigger is created to provide an incremental value based on two fields. In simplest terms, if col1 + col2 are the same, increment col3 by 1. Example output: 1|111|1001 2|111|1001 3|111|1001 4|111|1001 1|111|1002 2|111|1002 3|111|1002 4|111|1002 4|111|1003 The behavior on 11.50 works correctly. On 11.70 and 12.10 it appears to ignore the second column needed in the the trigger as it selects the column. Example output: 1|111|1001 2|111|1001 3|111|1001 4|111|1001 1|111|1001 2|111|1001 3|111|1001 4|111|1001 4|111|1001
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * Users having triggers in their application * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Update to IBM Informix Server 11.70.xC9 * ****************************************************************
Problem conclusion
Problem Fixed In IBM Informix Server 11.70.xC9
Temporary fix
Comments
APAR Information
APAR number
IT11265
Reported component name
INFORMIX SERVER
Reported component ID
5725A3900
Reported release
C10
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2015-09-16
Closed date
2017-06-09
Last modified date
2017-06-09
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
INFORMIX SERVER
Fixed component ID
5725A3900
Applicable component levels
RA10 PSN
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSGU8G","label":"Informix Servers"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"C10","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
09 June 2017